다기능 캐스케이드 히트펌프 시스템의 중간 열교환기 설정 온도 변화에 따른 에너지 성능 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김범준 | - |
dc.contributor.author | 조혜진 | - |
dc.contributor.author | 조수영 | - |
dc.contributor.author | 김세헌 | - |
dc.contributor.author | 정재원 | - |
dc.date.accessioned | 2023-08-01T07:09:45Z | - |
dc.date.available | 2023-08-01T07:09:45Z | - |
dc.date.created | 2023-07-20 | - |
dc.date.issued | 2022-11 | - |
dc.identifier.issn | 2713-4903 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/188694 | - |
dc.description.abstract | This study conducted determining the range of the intermediate heat exchanger temperature value of the multi-functional cascade heat pump system according to the design conditions of the residential building. In addition, the system performance and energy consumption according to the intermediate temperature change were analyzed. A residential building was set to 100m2 area. The thermal load of building was calculated by TRNSYS program. The thermodynamic equation and the EnergyPlus model equation were used for system analysis. The result showed that the optimal temperature range of the intermediate heat exchanger was 55℃~61℃ by various building design constraint. Since the energy consumption of the low-cycle compressor was dominant, the proposed system should be set to indoor unit conditions. | - |
dc.language | 한국어 | - |
dc.language.iso | ko | - |
dc.publisher | 대한설비공학회 | - |
dc.title | 다기능 캐스케이드 히트펌프 시스템의 중간 열교환기 설정 온도 변화에 따른 에너지 성능 분석 | - |
dc.title.alternative | Energy performance analysis of a multi-functional cascade heat pump system based on set-temperature variation of intermediate heat exchanger | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 정재원 | - |
dc.identifier.bibliographicCitation | 대한설비공학회 2022 동계학술발표대회 논문집, pp.60 - 63 | - |
dc.relation.isPartOf | 대한설비공학회 2022 동계학술발표대회 논문집 | - |
dc.citation.title | 대한설비공학회 2022 동계학술발표대회 논문집 | - |
dc.citation.startPage | 60 | - |
dc.citation.endPage | 63 | - |
dc.type.rims | ART | - |
dc.type.docType | Proceeding | - |
dc.description.journalClass | 2 | - |
dc.description.isOpenAccess | N | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | Cascade heat pump(캐스케이드 히트펌프) | - |
dc.subject.keywordAuthor | Multi-functional system(다기능 시스템) | - |
dc.subject.keywordAuthor | Intermediate heat exchanger(중간열교환기) | - |
dc.subject.keywordAuthor | Residential building(주거용 건물) | - |
dc.subject.keywordAuthor | Building energy-saving(건물에너지 절감) | - |
dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE11224651 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.