Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Dae Joong | - |
dc.contributor.author | Hwang, Kun | - |
dc.contributor.author | Kim, Hun | - |
dc.contributor.author | Cha, Jang Gy | - |
dc.contributor.author | Jang, Hyungseok | - |
dc.contributor.author | Park, Ju-Yong | - |
dc.contributor.author | Kim, Yeo Ju | - |
dc.date.accessioned | 2023-08-16T07:53:26Z | - |
dc.date.available | 2023-08-16T07:53:26Z | - |
dc.date.created | 2023-07-21 | - |
dc.date.issued | 2021-02 | - |
dc.identifier.issn | 1229-6929 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/189177 | - |
dc.description.abstract | Objective: To evaluate the signal intensity of the periosteum using ultrashort echo time pulse sequence with three-dimensional cone trajectory (3D UTE) with or without fat suppression (FS) to distinguish from artifacts in porcine tibias. Materials and Methods: The periosteum and overlying soft tissue of three porcine lower legs were partially peeled away from the tibial cortex. Another porcine tibia was prepared as three segments: with an intact periosteum outer and inner layer, with an intact periosteum inner layer, and without periosteum. Axial T1 weighted sequence (T1 WI) and 3D UTE (FS) were performed. Another porcine tibia without periosteum was prepared and subjected to 3D UTE (FS) and T1 WI twice, with positional changes. Two radiologists analyzed images to reach a consensus. Results: The three periosteal tissues that were partially peeled away from the cortex showed a high signal in 3D UTE (FS) and low signal on T1 WI. 3D UTE (FS) showed a high signal around the cortical surface with an intact outer and inner periosteum, and subtle high signals, mainly around the upper cortical surfaces with the inner layer of the periosteum and without periosteum. T1 WI showed no signal around the cortical surfaces, regardless of the periosteum state. The porcine tibia without periosteum showed changes in the high signal area around the cortical surface as the position changed in 3D UTE (FS). No signal was detected around the cortical surface in T1 WI, regardless of the position change. Conclusion: The periosteum showed a high signal in 3D UTE and 3D UTE FS that overlapped with artifacts around the cortical bone. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | KOREAN RADIOLOGICAL SOC | - |
dc.title | Depiction of the Periosteum Using Ultrashort Echo Time Pulse Sequence with Three-Dimensional Cone Trajectory and Histologic Correlation in a Porcine Model | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Yeo Ju | - |
dc.identifier.doi | 10.3348/kjr.2020.0640 | - |
dc.identifier.scopusid | 2-s2.0-85105760563 | - |
dc.identifier.wosid | 000688523100012 | - |
dc.identifier.bibliographicCitation | KOREAN JOURNAL OF RADIOLOGY, v.22, no.5, pp.782 - 791 | - |
dc.relation.isPartOf | KOREAN JOURNAL OF RADIOLOGY | - |
dc.citation.title | KOREAN JOURNAL OF RADIOLOGY | - |
dc.citation.volume | 22 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 782 | - |
dc.citation.endPage | 791 | - |
dc.type.rims | ART | - |
dc.type.docType | 정기학술지(Article(Perspective Article포함)) | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | EDDY CURRENTS | - |
dc.subject.keywordPlus | COMPONENTS | - |
dc.subject.keywordPlus | T-2 | - |
dc.subject.keywordPlus | MRI | - |
dc.subject.keywordAuthor | UTE | - |
dc.subject.keywordAuthor | Periosteum | - |
dc.subject.keywordAuthor | 3D cone trajectory | - |
dc.identifier.url | https://kjronline.org/DOIx.php?id=10.3348/kjr.2020.0640 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.