High contrast cleavage detection for enhancing porous silicon sensor sensitivity
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Layouni, Rabeb | - |
dc.contributor.author | Dubrovsky, Michael | - |
dc.contributor.author | Bao, Mengdi | - |
dc.contributor.author | Chung, Haejun | - |
dc.contributor.author | Du, Ke | - |
dc.contributor.author | Boriskina, Svetlana V. | - |
dc.contributor.author | Weiss, Sharon M. | - |
dc.contributor.author | Vermeulen, Diedrik | - |
dc.date.accessioned | 2023-08-16T08:01:58Z | - |
dc.date.available | 2023-08-16T08:01:58Z | - |
dc.date.created | 2023-07-21 | - |
dc.date.issued | 2021-01 | - |
dc.identifier.issn | 10944087 | - |
dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/189236 | - |
dc.description.abstract | Using porous silicon (PSi) interferometer sensors, we show the first experimental implementation of the high contrast cleavage detection (HCCD) mechanism. HCCD makes use of dramatic optical signal amplification caused by cleavage of high-contrast nanoparticle labeled reporters instead of the capture of low-index biological molecules. An approximately 2 nm reflectance peak shift was detected after cleavage of DNA-quantum dot reporters from the PSi surface via exposure to a 12.5 nM DNase enzyme solution. This signal change is 20 times greater than the resolution of the spectrometer used for the interferometric measurements, and the interferometric measurements agree with the response predicted by simulations and fluorescence measurements. These proof of principle experiments show a clear path to achieving a real-time, highly sensitive readout for a broad range of biological diagnostic assays that generate a signal via nucleic acid cleavage triggered by specific molecular binding events. | - |
dc.language | 영어 | - |
dc.language.iso | en | - |
dc.publisher | OPTICAL SOC AMER | - |
dc.title | High contrast cleavage detection for enhancing porous silicon sensor sensitivity | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Chung, Haejun | - |
dc.identifier.doi | 10.1364/OE.412469 | - |
dc.identifier.scopusid | 2-s2.0-85099075551 | - |
dc.identifier.wosid | 000605304600001 | - |
dc.identifier.bibliographicCitation | OPTICS EXPRESS, v.29, no.1, pp.1 - 11 | - |
dc.relation.isPartOf | OPTICS EXPRESS | - |
dc.citation.title | OPTICS EXPRESS | - |
dc.citation.volume | 29 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 1 | - |
dc.citation.endPage | 11 | - |
dc.type.rims | ART | - |
dc.type.docType | 정기학술지(Article(Perspective Article포함)) | - |
dc.description.journalClass | 1 | - |
dc.description.isOpenAccess | Y | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Optics | - |
dc.relation.journalWebOfScienceCategory | Optics | - |
dc.subject.keywordPlus | BIOSENSORS | - |
dc.identifier.url | https://opg.optica.org/oe/fulltext.cfm?uri=oe-29-1-1&id=444989 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1365
COPYRIGHT © 2021 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.