Cited 0 time in
액체식 제습 냉각시스템의 냉각탑 성능 개선을 통한 데이터센터 에너지 절감 효과 분석
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박효림 | - |
| dc.contributor.author | 정재원 | - |
| dc.contributor.author | 정재원 | - |
| dc.date.accessioned | 2023-09-04T07:54:46Z | - |
| dc.date.available | 2023-09-04T07:54:46Z | - |
| dc.date.created | 2023-07-20 | - |
| dc.date.issued | 2023-05 | - |
| dc.identifier.issn | 1975-3616 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/189995 | - |
| dc.description.abstract | This study proposes a cooling system that applies a liquid desiccant system to the free cooling system for data center cooling.While the free cooling system has the advantage of lower energy consumption than traditional cooling systems, it can sufferfrom performance degradation in hot and humid climates. The proposed system is a liquid desiccant based cooling systemapplied to the cooling tower, which improves the cooling tower's performance and efficiently saves cooling energy in hot andhumid climates. The proposed system uses lower cooling energy than the reference system, and as a result, it also helps reducepPUE compared to the reference system. | - |
| dc.language | 한국어 | - |
| dc.language.iso | ko | - |
| dc.publisher | 한국생태환경건축학회 | - |
| dc.title | 액체식 제습 냉각시스템의 냉각탑 성능 개선을 통한 데이터센터 에너지 절감 효과 분석 | - |
| dc.title.alternative | Energy Saving Investigation of Liquid Desiccant Cooling System with Performance Improvement for Data Center | - |
| dc.type | Article | - |
| dc.contributor.affiliatedAuthor | 정재원 | - |
| dc.identifier.bibliographicCitation | 한국생태환경건축학회 춘계학술발표대회 논문집, v.23, no.1, pp.68 - 69 | - |
| dc.relation.isPartOf | 한국생태환경건축학회 춘계학술발표대회 논문집 | - |
| dc.citation.title | 한국생태환경건축학회 춘계학술발표대회 논문집 | - |
| dc.citation.volume | 23 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 68 | - |
| dc.citation.endPage | 69 | - |
| dc.type.rims | ART | - |
| dc.type.docType | Proceeding | - |
| dc.description.journalClass | 2 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | other | - |
| dc.subject.keywordPlus | 액체식 제습 | - |
| dc.subject.keywordPlus | 냉각탑 | - |
| dc.subject.keywordPlus | 에너지 절감 | - |
| dc.subject.keywordPlus | 데이터센터 | - |
| dc.subject.keywordPlus | Liquid desiccant | - |
| dc.subject.keywordPlus | Cooling tower | - |
| dc.subject.keywordPlus | Energy saving | - |
| dc.subject.keywordPlus | Data center | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE11411975 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.