Cited 0 time in
Effect of Contrast Level and Image Format on a Deep Learning Algorithm for the Detection of Pneumothorax with Chest Radiography
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Yoon, Myeong Seong | - |
| dc.contributor.author | Kwon, Gitaek | - |
| dc.contributor.author | Oh, Jaehoon | - |
| dc.contributor.author | Ryu, Jongbin | - |
| dc.contributor.author | Lim, Jongwoo | - |
| dc.contributor.author | Kang, Bo Kyeong | - |
| dc.contributor.author | Lee, Juncheol | - |
| dc.contributor.author | Han, Dong-Kyoon | - |
| dc.date.accessioned | 2023-09-26T07:39:13Z | - |
| dc.date.available | 2023-09-26T07:39:13Z | - |
| dc.date.issued | 2023-06 | - |
| dc.identifier.issn | 0897-1889 | - |
| dc.identifier.issn | 1618-727X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/191080 | - |
| dc.description.abstract | Under the black-box nature in the deep learning model, it is uncertain how the change in contrast level and format affects the performance. We aimed to investigate the effect of contrast level and image format on the effectiveness of deep learning for diagnosing pneumothorax on chest radiographs. We collected 3316 images (1016 pneumothorax and 2300 normal images), and all images were set to the standard contrast level (100%) and stored in the Digital Imaging and Communication in Medicine and Joint Photographic Experts Group (JPEG) formats. Data were randomly separated into 80% of training and 20% of test sets, and the contrast of images in the test set was changed to 5 levels (50%, 75%, 100%, 125%, and 150%). We trained the model to detect pneumothorax using ResNet-50 with 100% level images and tested with 5-level images in the two formats. While comparing the overall performance between each contrast level in the two formats, the area under the receiver-operating characteristic curve (AUC) was significantly different (all p < 0.001) except between 125 and 150% in JPEG format (p = 0.382). When comparing the two formats at same contrast levels, AUC was significantly different (all p < 0.001) except 50% and 100% (p = 0.079 and p = 0.082, respectively). The contrast level and format of medical images could influence the performance of the deep learning model. It is required to train with various contrast levels and formats of image, and further image processing for improvement and maintenance of the performance. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Springer Verlag | - |
| dc.title | Effect of Contrast Level and Image Format on a Deep Learning Algorithm for the Detection of Pneumothorax with Chest Radiography | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1007/s10278-022-00772-y | - |
| dc.identifier.scopusid | 2-s2.0-85146863141 | - |
| dc.identifier.wosid | 000920627400001 | - |
| dc.identifier.bibliographicCitation | Journal of Digital Imaging, v.36, no.3, pp 1237 - 1247 | - |
| dc.citation.title | Journal of Digital Imaging | - |
| dc.citation.volume | 36 | - |
| dc.citation.number | 3 | - |
| dc.citation.startPage | 1237 | - |
| dc.citation.endPage | 1247 | - |
| dc.type.docType | Article; Early Access | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | QUALITY | - |
| dc.subject.keywordPlus | PACS | - |
| dc.subject.keywordAuthor | Deep learning | - |
| dc.subject.keywordAuthor | Pneumothorax | - |
| dc.subject.keywordAuthor | Image format | - |
| dc.subject.keywordAuthor | Contrast level | - |
| dc.subject.keywordAuthor | Artificial intelligence | - |
| dc.identifier.url | https://link.springer.com/article/10.1007/s10278-022-00772-y | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
