Cited 0 time in
Long-term outcomes and predictors of adverse events of EUS-guided hepatico-gastrostomy for malignant biliary obstruction: Multicenter, retrospective study
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Cho, Jae Hee | - |
| dc.contributor.author | Park, Se Woo | - |
| dc.contributor.author | Kim, Eui Joo | - |
| dc.contributor.author | Park, Chan Hyuk | - |
| dc.contributor.author | Park, Da Hae | - |
| dc.contributor.author | Lee, Kyong Joo | - |
| dc.contributor.author | Lee, Sang Soo | - |
| dc.date.accessioned | 2023-09-26T08:49:14Z | - |
| dc.date.available | 2023-09-26T08:49:14Z | - |
| dc.date.issued | 2022-12 | - |
| dc.identifier.issn | 0930-2794 | - |
| dc.identifier.issn | 1432-2218 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/191203 | - |
| dc.description.abstract | Background and Aims Endoscopic ultrasound (EUS)-guided hepaticogastrostomy (HGS) may be a feasible and useful alternative in patients with malignant biliary obstruction (MBO) after failed endoscopic retrograde cholangiopancreatography (ERCP). To date, the risk factors for adverse events (AEs) and long-term outcomes of EUS-HGS have not been fully explored according to stent type. Therefore, we evaluated potential risk factors for AEs and long-term outcomes of EUS-HGS. Methods In total, 120 patients who underwent EUS-HGS were retrospectively reviewed. A multivariate analysis through Cox proportional hazard and logistic regression model was used to identify the risk factors for stent dysfunction and AEs, respectively. Stent patency and patient survival were evaluated using Kaplan-Meier plots with a log-rank test for each stent. Results The technical and clinical success rates were 96.2% (102/106) and 83.0% (88/106). The median duration of stent patency was longer in self-expandable metal stents (SEMS) compared to plastic stents (PS) (158 vs. 108 days). Kaplan-Meier analysis indicated that the type of stent was not associated with stent patency (Hazard ratios [HR] 0.997, 95% confidence interval [CI] [0.525-1.896]) or overall survival. In addition, multivariate analysis indicated that hilar MBO significantly associated with stent dysfunction (HR, 2.340; 95% CI, 1.028-5.326, p = 0.043) and late AEs. Conclusions Given the lower incidence of AEs and better long-term outcomes of EUS-HGS, it can be considered a safe alternative to ERCP or percutaneous approaches regardless of which stent is used. Furthermore, hilar MBO was established as a potential risk factor for stent dysfunction and late AEs. | - |
| dc.format.extent | 9 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Springer Verlag | - |
| dc.title | Long-term outcomes and predictors of adverse events of EUS-guided hepatico-gastrostomy for malignant biliary obstruction: Multicenter, retrospective study | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1007/s00464-022-09346-z | - |
| dc.identifier.scopusid | 2-s2.0-85131572256 | - |
| dc.identifier.wosid | 000808394400005 | - |
| dc.identifier.bibliographicCitation | Surgical Endoscopy, v.36, no.12, pp 8950 - 8958 | - |
| dc.citation.title | Surgical Endoscopy | - |
| dc.citation.volume | 36 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 8950 | - |
| dc.citation.endPage | 8958 | - |
| dc.type.docType | Article; Early Access | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Surgery | - |
| dc.relation.journalWebOfScienceCategory | Surgery | - |
| dc.subject.keywordPlus | COVERED METAL STENT | - |
| dc.subject.keywordPlus | PLASTIC STENT | - |
| dc.subject.keywordPlus | DRAINAGE | - |
| dc.subject.keywordPlus | HEPATICOGASTROSTOMY | - |
| dc.subject.keywordPlus | ERCP | - |
| dc.subject.keywordPlus | SAFETY | - |
| dc.subject.keywordPlus | EFFICACY | - |
| dc.subject.keywordAuthor | Endoscopic ultrasound | - |
| dc.subject.keywordAuthor | Hepaticogastrostomy | - |
| dc.subject.keywordAuthor | Biliary obstruction | - |
| dc.subject.keywordAuthor | Risk factor | - |
| dc.subject.keywordAuthor | Stent | - |
| dc.identifier.url | https://link.springer.com/article/10.1007/s00464-022-09346-z | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.