Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Design and SAR Analysis of AMC-Based Fabric Antenna for Body-Centric Communicationopen access

Authors
Ali, UsmanUllah, SadiqBasir, AbdulKamal, BabarMatekovits, LadislauYoo, Hyoungsuk
Issue Date
Jul-2023
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Keywords
Artificial magnetic conductor (AMC); body-centric communication; felt; CST MWS; specific absorption rate (SAR); healthcare; IoT
Citation
IEEE ACCESS, v.11, pp.73894 - 73911
Indexed
SCIE
SCOPUS
Journal Title
IEEE ACCESS
Volume
11
Start Page
73894
End Page
73911
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/191280
DOI
10.1109/ACCESS.2023.3295993
ISSN
2169-3536
Abstract
This study focused on the design and analysis of an artificial magnetic conductor (AMC)-based fabric antenna for body-centric communication. The antenna was made of felt and had a loss tangent of 0.044 and relative permittivity of 1.3. The proposed antenna was built to function in the frequency band centered at 2.45 GHz, widely used in wireless communication devices. The antenna’s performance was evaluated using the electromagnetic simulation software CST MWS. A 50 Ω SubMiniature version connector was used to excite the proposed antenna. A 2×2 AMC array was integrated into the antenna below it to improve its performance in terms of radiation efficiency, gain, and backward radiation reduction. The antenna and AMC array were fabricated on flexible fabric substrates. The total volume of the AMC-integrated antenna is 0.55λo×0.55λo×0.016λo . It was demonstrated that adding an AMC array enhanced the radiation properties of the antenna and significantly decreased its back lobes. The on- and off-body maximum gains of the AMC-integrated antenna are (≥ 4.11 dBi) and 5.23 dBi, respectively. Furthermore, employing the AMC array, a significant reduction in the specific absorption rate value, which is (≤ 0.43 W/kg) for human body tissue chest/back and (≤ 0.75 W/kg) for human body tissue arm, was obtained, ensuring safety for human use. The simulated and measured results were in agreement. The tested on- and off-body radiation efficiencies in the frequency band centered at 2.45 GHz is (>67%) and (>83%), respectively. The proposed antenna can potentially be used in various applications such as healthcare monitoring, wearable electronics, and Internet of Things (IoT) systems, where reliable and efficient communication is required in a body-centric environment.
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Hyoungsuk photo

Yoo, Hyoungsuk
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE