| dc.description.abstract | The equivalent static load for non-structural elements has a limitation in that the sloshing effect and the interaction between the fluid and the water tank cannot be considered. In this study, the equations to evaluate the impulse and convective components in the design codes and previous research were compared with the shaking table test results of a rectangular water tank with flexible wall panels. The conclusions of this study can be summarized as follows: (1) It was observed that the natural periods of the impulsive component according to ACI 350.3 were longer than system identification results. Thus, ACI 350.3 may underestimate the earthquake load in the case of water tanks with flexible walls. (2) In the case of water tanks with flexible walls, the side walls deform due to bending of the front and back walls. When such three-dimensional fluid-structure interaction was included, the natural period of the impulsive component became similar to the experimental results. (3) When a detailed finite element (FE) model of the water tank was unavailable, the assumption could be used, resulting in a reasonably conservative design earthquake load. | - |
| dc.format.extent | 8 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국지진공학회 | - |
| dc.title | 유연한 벽면을 가진 사각형 물탱크의 설계지진력 산정 | - |
| dc.title.alternative | Seismic Design Force for Rectangular Water Tank with Flexible Walls | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5000/EESK.2023.27.6.303 | - |
| dc.identifier.scopusid | 2-s2.0-105040623106 | - |
| dc.identifier.bibliographicCitation | 한국지진공학회논문집, v.27, no.6, pp 303 - 310 | - |
| dc.citation.title | 한국지진공학회논문집 | - |
| dc.citation.volume | 27 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 303 | - |
| dc.citation.endPage | 310 | - |
| dc.identifier.kciid | ART003012154 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Rectangular water tank with flexible boundary | - |
| dc.subject.keywordAuthor | Sloshing effect | - |
| dc.subject.keywordAuthor | System identification | - |
| dc.subject.keywordAuthor | Finite element model | - |
| dc.subject.keywordAuthor | Design seismic force | - |
| dc.identifier.url | http://www.eesk-j.or.kr/journal/article.php?code=87774 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.