Cited 0 time in
Corrigendum to “PtS-decorated WS2 microflakes based sensors for selective ammonia detection at room temperature” [Sens. Actuators B Chem. 394 (2023) 134399] (Sensors and Actuators: B. Chemical (2023) 394, (S0925400523011140), (10.1016/j.snb.2023.134399))
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Guang, Qiyilan | - |
| dc.contributor.author | Huang, Baoyu | - |
| dc.contributor.author | Yu, Jun | - |
| dc.contributor.author | Bonyani, Maryam | - |
| dc.contributor.author | Moaddeli, Mohammad | - |
| dc.contributor.author | Kanani, Mansour | - |
| dc.contributor.author | Mirzaei, Ali | - |
| dc.contributor.author | Kim, Hyoun Woo | - |
| dc.contributor.author | Kim, Sang Sub | - |
| dc.contributor.author | Li, Xiaogan | - |
| dc.date.accessioned | 2023-11-14T08:17:59Z | - |
| dc.date.available | 2023-11-14T08:17:59Z | - |
| dc.date.issued | 2024-01 | - |
| dc.identifier.issn | 0925-4005 | - |
| dc.identifier.issn | 1873-3077 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/192192 | - |
| dc.description.abstract | The authors regret Question 1: sentence should be changed to As the WS2 microflakes used in this study is the same WS2 product selected in our previous studies, the diameter of WS2 microflakes was 0.4–4.3 micrometers from the statistical analysis of the previous study [25,26]. [26] Q. Guang, B. Huang, J. Yu, J. Zhang, X. Li, Indium Oxide Decorated WS2 Microflakes for Selective Ammonia Sensors at Room Temperature, Chemsensors, 10 (10) (2022) 402. Then, other reference numbers should be corrected to be in order accordingly throughout the text. Response 1: Thanks for the professional comment. The highlighted part on page 6 of the paper shown in bellow is corrected as follows: As the WS2 microflakes used in this study is the same WS2 product selected in our previous studies, the diameter of WS2 microflakes was 0.4–4.3 micrometers from the statistical analysis of the previous study [25,26]. [26] Q. Guang, B. Huang, J. Yu, J. Zhang, X. Li, Indium Oxide Decorated WS2 Microflakes for Selective Ammonia Sensors at Room Temperature, Chemsensors, 10 (10) (2022) 402. Furthermore, because we insert a new reference into the article and mark it as a reference [26]. So, the serial number of all references after reference [26] (including reference [26]) in the original article should be added by 1. For example, the original reference [26] should become reference [27], and the original reference [27] should become reference [28], and so on increase the serial number of all references. [Formula presented] The authors would like to apologize for any inconvenience caused. | - |
| dc.format.extent | 2 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Corrigendum to “PtS-decorated WS2 microflakes based sensors for selective ammonia detection at room temperature” [Sens. Actuators B Chem. 394 (2023) 134399] (Sensors and Actuators: B. Chemical (2023) 394, (S0925400523011140), (10.1016/j.snb.2023.134399)) | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.1016/j.snb.2023.134764 | - |
| dc.identifier.scopusid | 2-s2.0-85173990321 | - |
| dc.identifier.wosid | 001114588300001 | - |
| dc.identifier.bibliographicCitation | Sensors and Actuators, B: Chemical, v.398, pp 1 - 2 | - |
| dc.citation.title | Sensors and Actuators, B: Chemical | - |
| dc.citation.volume | 398 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 2 | - |
| dc.type.docType | Correction | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Electrochemistry | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S092540052301482X?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
