Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Three-Dimensional Quantitative Assessment of Pedicle Screw Accuracy in Clinical Utilization of a New Robotic System in Spine Surgery A Multicenter Studyopen access

Authors
Ha, Byeong-JinLee, Jong-MinYoon, Seon-JinKim, Byung-KwanLee, JunseokLee, Su hunRyu, SeungjaeCha, YongyeobHwang, SungteacWoo, DonggiLee, Chang KyuShin, Dong AhHa, YoonKuh, Sung UkKim, Keung NyunSon, DongwukYi, Seong
Issue Date
Sep-2023
Publisher
KOREAN SPINAL NEUROSURGERY SOC
Keywords
Robot-assisted spine surgery; Pedicle screws; Dimensional measurement accuracy
Citation
NEUROSPINE, v.20, no.3, pp.1028 - 1039
Indexed
SCIE
SCOPUS
KCI
Journal Title
NEUROSPINE
Volume
20
Number
3
Start Page
1028
End Page
1039
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/192200
DOI
10.14245/ns.2346552.276
ISSN
2586-6583
Abstract
Objective: The objective of this study was to evaluate the accuracy of pedicle screw placement in patients undergoing percutaneous pedicle screw fixation with robotic guidance, using a newly developed 3-dimensional quantitative measurement system. The study also aimed to assess the clinical feasibility of the robotic system in the field of spinal surgery.Methods: A total of 113 patients underwent pedicle screw insertion using the CUVIS-spine pedicle screw guide system (CUREXO Inc.). Intraoperative O-arm images were obtained, and screw insertion pathways were planned accordingly. Image registration was performed using paired-point registration and iterative closest point methods. The accuracy of the robotic-guided pedicle screw insertion was assessed using 3-dimensional offset calculation and the Gertzbein-Robbins system (GRS).Results: A total of 448 screws were inserted in the 113 patients. The image registration success rate was 95.16%. The average error of entry offset was 2.86 mm, target offset was 2.48 mm, depth offset was 1.99 mm, and angular offset was 3.07 degrees. According to the GRS grading system, 88.39% of the screws were classified as grade A, 9.60% as grade B, 1.56% as grade C, 0.22% as grade D, and 0.22% as grade E. Clinically acceptable screws (GRS grade A or B) accounted for 97.54% of the total, with no reported neurologic complications. Conclusion: Our study demonstrated that pedicle screw insertion using the novel robot -assisted navigation method is both accurate and safe. Further prospective studies are necessary to explore the potential benefits of this robot-assisted technique in comparison to conventional approaches.
Files in This Item
Appears in
Collections
ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jong Min photo

Lee, Jong Min
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE