Cited 0 time in
초음파를 이용한 팬텀 근육 내 주입한 초음파 젤 부피 계측: 예비연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 이희제 | - |
| dc.contributor.author | 안새미 | - |
| dc.contributor.author | 류정아 | - |
| dc.contributor.author | 박태수 | - |
| dc.date.accessioned | 2024-01-10T03:37:44Z | - |
| dc.date.available | 2024-01-10T03:37:44Z | - |
| dc.date.issued | 2016-08 | - |
| dc.identifier.issn | 1226-2102 | - |
| dc.identifier.issn | 2005-8918 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/194128 | - |
| dc.description.abstract | Purpose The purpose of this study is to check the intermuscular fluid collection in a phantom using ultrasound after comparison with the original injected volume of gel and to evaluate interobserver reliability. Materials and Methods One orthopedic surgeon injected ultrasonographic gel into the muscle of slaughtered cow meat using a syringe and needle, and recorded the injected volume. The injected volume of gel ranged from 1 ml to 5 ml, and total number of trials was 30 times. The volume was calculated using ultrasound by two experienced radiologists. The ultrasonographic measured volme was assessed and interobserver variability was measured. Results The mean ultrasonographic measured volume was 71.35% of the original injected volume of gel. Thus, the measured volume using ultrasound showed a tendency to underestimate the injected volume into the muscle. For evaluation of interobserver reliability, interclass correlation using SPSS and consistency using Bland and Altman plot were calculated. Interclass correlation was 0.95, and Bland and Altman plot showed that the differences of mean volume measured by two observers were within ±1.96 standard deviation over 95%. Therefore, it showed good interoberver reliability. Conclusion Ultrasonographic measurement of the intramuscular fluid collection in a phantom showed mean 71.35% of the original injected volume of gel, and it tended to be underestimated in proportion to the increased volume of intermuscular gel. This study showed good interobserver reliability. | - |
| dc.format.extent | 5 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한정형외과학회 | - |
| dc.title | 초음파를 이용한 팬텀 근육 내 주입한 초음파 젤 부피 계측: 예비연구 | - |
| dc.title.alternative | Ultrasonographic Measurements of the Intramuscular Fluid Collection Using a Phantom: A Preliminary Study | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.4055/jkoa.2016.51.4.315 | - |
| dc.identifier.bibliographicCitation | 대한정형외과학회지, v.51, no.4, pp 315 - 319 | - |
| dc.citation.title | 대한정형외과학회지 | - |
| dc.citation.volume | 51 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 315 | - |
| dc.citation.endPage | 319 | - |
| dc.identifier.kciid | ART002144637 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 근육내 젤 저류 | - |
| dc.subject.keywordAuthor | 계측 | - |
| dc.subject.keywordAuthor | 관찰자 간 일치도 | - |
| dc.subject.keywordAuthor | 초음파 | - |
| dc.subject.keywordAuthor | intermuscular gel collection | - |
| dc.subject.keywordAuthor | measurement | - |
| dc.subject.keywordAuthor | interobserver reliability | - |
| dc.subject.keywordAuthor | ultrasonography | - |
| dc.identifier.url | https://jkoa.org/DOIx.php?id=10.4055/jkoa.2016.51.4.315 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
