Cited 0 time in
Korean-specific iodine S values for use in internal dosimetry
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kwon, Tae-Eun | - |
| dc.contributor.author | Chung, Yoonsun | - |
| dc.contributor.author | Lee, Choonsik | - |
| dc.date.accessioned | 2024-01-11T05:00:33Z | - |
| dc.date.available | 2024-01-11T05:00:33Z | - |
| dc.date.issued | 2023-12 | - |
| dc.identifier.issn | 1738-5733 | - |
| dc.identifier.issn | 2234-358X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/194369 | - |
| dc.description.abstract | The use of iodine S values derived using the International Commission Radiological Protection (ICRP) phantoms may introduce significant bias in internal dosimetry for Koreans due to anatomical variability. In the current study, we produced an extensive dataset of Korean S values for selected five iodine radioisotopes (I-125, I-129, I-131, I-133, and I-134) for use in radiation protection. To calculate S values, we implemented Monte Carlo simulations using the Mesh-type Reference Korean Phantoms (MRKPs), developed in a high-quality/fidelity mesh format. Noticeable differences were observed in S value comparisons between the Korean and ICRP reference phantoms with ratios (Korean/ICRP) widely ranging from 0.16 to 6.2. The majority of S value ratios were lower than the unity in Korean phantoms (interquartile range = 0.47-1.28; mean = 0.96; median = 0.69). The S values provided in the current study will be extensively utilized in iodine internal dosimetry for Koreans. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국원자력학회 | - |
| dc.title | Korean-specific iodine S values for use in internal dosimetry | - |
| dc.title.alternative | Korean-specific iodine S values for use in internal dosimetry | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1016/j.net.2023.09.005 | - |
| dc.identifier.scopusid | 2-s2.0-85171993647 | - |
| dc.identifier.wosid | 001127858300001 | - |
| dc.identifier.bibliographicCitation | Nuclear Engineering and Technology, v.55, no.12, pp 4659 - 4663 | - |
| dc.citation.title | Nuclear Engineering and Technology | - |
| dc.citation.volume | 55 | - |
| dc.citation.number | 12 | - |
| dc.citation.startPage | 4659 | - |
| dc.citation.endPage | 4663 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART003017888 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordPlus | COLOR SLICE IMAGES | - |
| dc.subject.keywordPlus | ADULTS | - |
| dc.subject.keywordAuthor | Internal exposure | - |
| dc.subject.keywordAuthor | Korean phantoms | - |
| dc.subject.keywordAuthor | Specific Absorbed Fraction | - |
| dc.subject.keywordAuthor | Thyroid dose | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S173857332300414X?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
