Cited 0 time in
Cardiac Electrical And Structural Changes after Iodinated Contrast Media Administration: A Longitudinal Cohort Analysis
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Inoue, Kosuke | - |
| dc.contributor.author | Bashir, Muhammad T. | - |
| dc.contributor.author | Warner, Alberta L. | - |
| dc.contributor.author | Ebrahimi, Ramin | - |
| dc.contributor.author | Neverova, Natalia V. | - |
| dc.contributor.author | Currier, Jesse W. | - |
| dc.contributor.author | Sohn, Seo Young | - |
| dc.contributor.author | Rhee, Connie M. | - |
| dc.contributor.author | Lee, Martin L. | - |
| dc.contributor.author | Leung, Angela M. | - |
| dc.date.accessioned | 2024-11-28T08:36:40Z | - |
| dc.date.available | 2024-11-28T08:36:40Z | - |
| dc.date.issued | 2024-09 | - |
| dc.identifier.issn | 1050-7256 | - |
| dc.identifier.issn | 1557-9077 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/195486 | - |
| dc.description.abstract | Background: Iodinated contrast is commonly used for radiological procedures, with one dose delivering several hundred-fold the daily requirements needed for normal thyroid hormone production. Risks of excess iodine include incident thyroid dysfunction, which is associated with adverse cardiac outcomes, yet there are no prospective studies investigating the changes in cardiac physiology following iodine contrast administration. This study was conducted to investigate the longitudinal relationships between the amount of iodinated contrast administration and changes in cardiac electrophysiology and structure. Methods: A longitudinal cohort study was conducted with prospectively enrolled participants who received iodine contrast for elective computed tomography or coronary angiography. Serum thyroid function tests, electrocardiograms (EKG), and transthoracic echocardiograms were obtained serially until 36 months. Trends of electrical and structural cardiac changes following iodine contrast administration were assessed using mixed effect models. Results: The cohort was composed of 129 patients (median age, 70 [interquartile range: 63, 75] years; 98% male). Larger amounts of iodine exposure were associated with increases in QRS and QTc durations and decreased ejection fraction (EF), and these associations were still observed for follow-up EF after additionally adjusting for baseline values (the high-iodine contrast group vs. the low-iodine contrast group, -4.23% [confidence interval, -7.66% to -0.79%]). Dose–response analyses also showed lower EF with larger amounts of iodine received; these trends were not significant for the EKG parameters studied. Conclusions: Over a period of up to 36 months, a larger amount of administered iodine contrast was associated with lower EF among participants. Further investigation is needed to elucidate the long-term trends of electrical and structural cardiac function after iodine contrast administration. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Mary Ann Liebert Inc. | - |
| dc.title | Cardiac Electrical And Structural Changes after Iodinated Contrast Media Administration: A Longitudinal Cohort Analysis | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1089/thy.2024.0131 | - |
| dc.identifier.scopusid | 2-s2.0-85202678063 | - |
| dc.identifier.wosid | 001298400700001 | - |
| dc.identifier.bibliographicCitation | Thyroid, v.34, no.9, pp 1163 - 1170 | - |
| dc.citation.title | Thyroid | - |
| dc.citation.volume | 34 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 1163 | - |
| dc.citation.endPage | 1170 | - |
| dc.type.docType | Article; Early Access | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Endocrinology & Metabolism | - |
| dc.relation.journalWebOfScienceCategory | Endocrinology & Metabolism | - |
| dc.subject.keywordPlus | SUBCLINICAL HYPOTHYROIDISM | - |
| dc.subject.keywordPlus | CARDIOVASCULAR EVENTS | - |
| dc.subject.keywordPlus | THYROID-FUNCTION | - |
| dc.subject.keywordPlus | HEART-DISEASE | - |
| dc.subject.keywordPlus | RISK | - |
| dc.subject.keywordPlus | HYPERTHYROIDISM | - |
| dc.subject.keywordPlus | FAILURE | - |
| dc.subject.keywordAuthor | echocardiography | - |
| dc.subject.keywordAuthor | electrocardiogram | - |
| dc.subject.keywordAuthor | iodine | - |
| dc.subject.keywordAuthor | iodine contrast media | - |
| dc.subject.keywordAuthor | thyroid | - |
| dc.identifier.url | https://www.liebertpub.com/doi/10.1089/thy.2024.0131 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
