Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Full-duplex enabled wireless power transfer system via textile for miniaturized IMD

Full metadata record
DC Field Value Language
dc.contributor.author이재호-
dc.contributor.authorBae, Beomjun-
dc.contributor.authorKim, Beomjin-
dc.contributor.authorLee, Byunghun-
dc.date.accessioned2024-11-28T10:31:44Z-
dc.date.available2024-11-28T10:31:44Z-
dc.date.issued2022-08-
dc.identifier.issn2093-9868-
dc.identifier.issn2093-985X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/196146-
dc.description.abstractFull-duplex (FD) enabled wireless power transfer (WPT) system via textile for miniaturized IMD is presented. By utilizing the battery-free near-field communication (NFC) method, the system realizes wireless power and data transmission without a bulky battery or energy harvester which can diminish the physical size of implantable medical device ( IMD). Moreover, using textile as a medium of power transmission, the system overcomes the drawback and extends the limited effective range of the NFC method. In addition, as realizing simultaneous bidirectional data transmission over a single data channel, IMD has been further miniaturized. The proposed system including an external transmitter and the minimized IMD receiver supports 200 kbps and 50 kbps data rates for FSK downlink and LSK uplink telemetries at the same time with bit error rate (BER) of < 8 x 10(-5) and < 4 x 10(-5), respectively. The measured power transfer efficiency (PTE) and DC-to-DC power delivered to load (PDL) are 5.77% and 64 mW at 0.5/60 cm of vertical/horizontal distance.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisher대한의용생체공학회-
dc.titleFull-duplex enabled wireless power transfer system via textile for miniaturized IMD-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.1007/s13534-022-00237-9-
dc.identifier.scopusid2-s2.0-85134500545-
dc.identifier.wosid000827469900001-
dc.identifier.bibliographicCitationBiomedical Engineering Letters (BMEL), v.12, no.SI 3, pp 295 - 302-
dc.citation.titleBiomedical Engineering Letters (BMEL)-
dc.citation.volume12-
dc.citation.numberSI 3-
dc.citation.startPage295-
dc.citation.endPage302-
dc.type.docTypeArticle-
dc.identifier.kciidART002958496-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryEngineering, Biomedical-
dc.subject.keywordPlusINDUCTIVE POWER-
dc.subject.keywordPlusTRANSMISSION-
dc.subject.keywordPlusMODULATION-
dc.subject.keywordPlusLINK-
dc.subject.keywordPlusNFC-
dc.subject.keywordAuthorFull duplex-
dc.subject.keywordAuthorWireless power transfer-
dc.subject.keywordAuthorConductive thread-
dc.subject.keywordAuthorTextile coil-
dc.subject.keywordAuthorData telemetry-
dc.subject.keywordAuthorImplantable medical device-
dc.subject.keywordAuthorDual-band-
dc.subject.keywordAuthorNear-field-communication method-
dc.subject.keywordAuthorRadio frequency technology-
dc.identifier.urlhttps://link.springer.com/article/10.1007/s13534-022-00237-9-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Byunghun photo

Lee, Byunghun
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE