Cited 0 time in
분자체를 이용한 LNG 액화 플랜트 탈수 공정의 효율성 향상에 관한 연구
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 박종화 | - |
| dc.contributor.author | 유돈상 | - |
| dc.contributor.author | 조대명 | - |
| dc.date.accessioned | 2024-11-28T13:01:17Z | - |
| dc.date.available | 2024-11-28T13:01:17Z | - |
| dc.date.issued | 2024-02 | - |
| dc.identifier.issn | 1738-7264 | - |
| dc.identifier.issn | 2288-7407 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/196433 | - |
| dc.description.abstract | The natural gas dehydration process plays a central role in liquefying LNG. This study proposes two natural gas dehydration process systems applicable to liquefied natural gas (LNG) liquefaction plants, and compares and analyzes energy optimization measures through simulation. The fuel gas from feed stream (FFF) case, which requires additional equipment for gas circulation, disadvantages are design capacity and increased energy. On the other hand, the end flash gas (EFG) case has advantages such as low initial investment costs and no need for compressors, but has downsides such as increased power energy and the use of gas with different components. According to the process simulation results, the required energy is 33.22 MW for the FFF case and 32.86 MW for the EFG case, confirming 1.1% energy savings per unit time in the EFG case. Therefore, in terms of design pressure, capacity, device configuration, and required energy, the EFG case is relatively advantageous. However, further research is needed on the impact of changes in the composition of regenerated gas on the liquefaction process and the fuel gas system. | - |
| dc.format.extent | 9 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 한국수소및신에너지학회 | - |
| dc.title | 분자체를 이용한 LNG 액화 플랜트 탈수 공정의 효율성 향상에 관한 연구 | - |
| dc.title.alternative | Study on the Improvement of Efficiency in Dehydration Process of LNG Liquefaction Plant Using Molecular Sieve | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.7316/JHNE.2024.35.1.105 | - |
| dc.identifier.bibliographicCitation | 한국수소및신에너지학회논문집, v.35, no.1, pp 105 - 113 | - |
| dc.citation.title | 한국수소및신에너지학회논문집 | - |
| dc.citation.volume | 35 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 105 | - |
| dc.citation.endPage | 113 | - |
| dc.identifier.kciid | ART003053069 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | 액화 천연가스 | - |
| dc.subject.keywordAuthor | 탈수 공정 | - |
| dc.subject.keywordAuthor | 플랜트 공정 모사 | - |
| dc.subject.keywordAuthor | 분자체 | - |
| dc.subject.keywordAuthor | LNG | - |
| dc.subject.keywordAuthor | Dehydration process | - |
| dc.subject.keywordAuthor | Plant process modeling | - |
| dc.subject.keywordAuthor | Molecular sieve | - |
| dc.identifier.url | https://journal.hydrogen.or.kr/_common/do.php?a=full&b=12&bidx=3571&aidx=39697 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.