Cited 0 time in
Applicability performance evaluation of cascade heat pump for building electrification in winter
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Beom-Jun | - |
| dc.contributor.author | Kim, Seheon | - |
| dc.contributor.author | Go, Mingeon | - |
| dc.contributor.author | Joo, Hong-Jin | - |
| dc.contributor.author | Jeong, Jae-Weon | - |
| dc.date.accessioned | 2024-11-28T13:31:03Z | - |
| dc.date.available | 2024-11-28T13:31:03Z | - |
| dc.date.issued | 2024-04 | - |
| dc.identifier.issn | 2352-7102 | - |
| dc.identifier.issn | 2352-7102 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/196553 | - |
| dc.description.abstract | This study aimed to evaluate the performance of indoor air heating and domestic hot water supply using a cascade heat pump system. The focus was on using existing heat pump equipment to satisfy system requirements in the context of building retrofitting. The experimental setup was located in nearly net-zero experimental building of the South Korea. The system was configured to heat air in the low-cycle heat pump and supply hot domestic water in the high-cycle heat pump. The study compared three operational modes: a low-cycle-only mode; a hot water-only mode; and a combined mode. While low-cycle-only mode and hot-water-only mode fulfilled the required condition with 3.94–5.38 COP and 60 °C hot water temperature with a flow rate of 15.8 LPM separately, the combined mode failed to reach the target air temperature fulfilling only hot water temperature. In conclusion, the system demonstrated satisfactory performance when heating indoor air and providing hot water separately. However, the indoor heating performance declined when both functions were operated simultaneously. To address this issue, possible solutions could include revising the system operation logic to better align with heating and domestic hot water usage schedules or altering the refrigerant flow path. | - |
| dc.format.extent | 17 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Applicability performance evaluation of cascade heat pump for building electrification in winter | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.jobe.2023.108406 | - |
| dc.identifier.scopusid | 2-s2.0-85181164956 | - |
| dc.identifier.wosid | 001165650000001 | - |
| dc.identifier.bibliographicCitation | Journal of Building Engineering, v.82, pp 1 - 17 | - |
| dc.citation.title | Journal of Building Engineering | - |
| dc.citation.volume | 82 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 17 | - |
| dc.type.docType | Article; Early Access | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Construction & Building Technology | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalWebOfScienceCategory | Construction & Building Technology | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
| dc.subject.keywordPlus | Air source heat pumps | - |
| dc.subject.keywordPlus | Pumps | - |
| dc.subject.keywordPlus | Water supply | - |
| dc.subject.keywordPlus | Water temperature | - |
| dc.subject.keywordAuthor | Cascade heat pump system | - |
| dc.subject.keywordAuthor | Field experiment study | - |
| dc.subject.keywordAuthor | Heating performance | - |
| dc.subject.keywordAuthor | Residential building | - |
| dc.subject.keywordAuthor | System retrofitting | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S2352710223025895?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.