Reduction of Fine Dust and Alleviation of Heat Island Effect: An Analysis of Cold Air Flow in Pohang City, South Korea

Full metadata record
DC Field Value Language
dc.contributor.authorJung, Woonkun-
dc.contributor.authorKim, Gunwoo-
dc.date.accessioned2024-11-28T14:31:29Z-
dc.date.available2024-11-28T14:31:29Z-
dc.date.issued2024-03-
dc.identifier.issn2073-445X-
dc.identifier.issn2073-445X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/196950-
dc.description.abstractThe urban heat island (UHI) effect poses a significant challenge for cities like Pohang, South Korea, which suffer from environmental pollution. Integrating a ventilation corridor into city planning can mitigate this issue. Despite wind’s potential as a resource for urban areas, its role remains under-studied in urban planning and design. To address this gap, this study analyzes the wind environment of Pohang City to identify effective strategies for reducing the UHI effect through the implementation of wind corridors, thereby enhancing the city’s thermal environment and sustainability. We used the KLAM_21 model to simulate and analyze the cold airflow. The results indicate that the land cover of Pohang, including residential and commercial areas, consists of urbanized dry areas. The wind direction over the past 10 years (2013–2022) has generally been west–southwest (247.5°). The cold air height and flow direction range expanded around the Hyeongsan River, eventually affecting the central city after 5 h. In the simulations, cold air accumulated above 30 m at specific locations near the valley’s base. After 2 h, the flow range of the cold air height increased. The green area ratio (GAR) and cold air speed positively correlated (+0.153). Thus, creating a wind-corridor forest could effectively address Pohang’s fine dust and UHI phenomena.-
dc.format.extent32-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI AG-
dc.titleReduction of Fine Dust and Alleviation of Heat Island Effect: An Analysis of Cold Air Flow in Pohang City, South Korea-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/land13030347-
dc.identifier.scopusid2-s2.0-85189181078-
dc.identifier.wosid001192993300001-
dc.identifier.bibliographicCitationLand, v.13, no.3, pp 1 - 32-
dc.citation.titleLand-
dc.citation.volume13-
dc.citation.number3-
dc.citation.startPage1-
dc.citation.endPage32-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassssci-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalWebOfScienceCategoryEnvironmental Studies-
dc.subject.keywordPlusNorth Kyongsang-
dc.subject.keywordPlusPohang-
dc.subject.keywordPlusSouth Korea-
dc.subject.keywordAuthorcold air-
dc.subject.keywordAuthorcorrelation analysis-
dc.subject.keywordAuthorfine dust-
dc.subject.keywordAuthorflow analysis-
dc.subject.keywordAuthorgreen area ratio (GAR)-
dc.subject.keywordAuthorKLAM_21 model-
dc.subject.keywordAuthorPohang-si-
dc.subject.keywordAuthorSouth Korea-
dc.subject.keywordAuthorurban heat island-
dc.subject.keywordAuthorwind corridor-
dc.identifier.urlhttps://www.mdpi.com/2073-445X/13/3/347-