Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Organic X-Ray Image Sensors Using a Medium Bandgap Polymer Donor with Low Dark Current

Full metadata record
DC Field Value Language
dc.contributor.authorHa, Jong-Woon-
dc.contributor.authorEom, Seung Hun-
dc.contributor.authorCha, Bo Kyung-
dc.contributor.authorSong, Seyeong-
dc.contributor.authorEun, Hyeong Ju-
dc.contributor.authorKim, Jong H.-
dc.contributor.authorPark, Jong Mok-
dc.contributor.authorKim, Bongsoo-
dc.contributor.authorPark, Byoungwook-
dc.contributor.authorKo, Seo-Jin-
dc.contributor.authorYoon, Sung Cheol-
dc.contributor.authorLee, Changjin-
dc.contributor.authorJung, In Hwan-
dc.contributor.authorHwang, Do-Hoon-
dc.date.accessioned2024-11-28T15:31:43Z-
dc.date.available2024-11-28T15:31:43Z-
dc.date.issued2024-05-
dc.identifier.issn2575-0356-
dc.identifier.issn2575-0356-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/197335-
dc.description.abstractThe development of portable X-ray detectors is necessary for diagnosing fractures in unconscious patients in emergency situations. However, this is quite challenging because of the heavy weight of the scintillator and silicon photodetectors. The weight and thickness of X-ray detectors can be reduced by replacing the silicon layer with an organic photodetectors. This study presents a novel bithienopyrroledione-based polymer donor that exhibits excellent photodetection properties even in a thick photoactive layer (similar to 700 nm), owing to the symmetric backbone and highly soluble molecular structure of bithienopyrroledione. The ability of bithienopyrroledione-based polymer donor to strongly suppress the dark current density (J(d) similar to 10(-10) A cm(-2)) at a negative bias (-2.0 V) while maintaining high responsivity (R = 0.29 A W-1) even at a thickness of 700 nm results in a maximum shot-noise-limited specific detectivity of D-sh* = 2.18 x 10(13) Jones in the organic photodetectors. Printed organic photodetectors are developed by slot-die coating for use in X-ray detectors, which exhibit D-sh* = 2.73 x 10(12) Jones with clear rising (0.26 s) and falling (0.29 s) response times upon X-ray irradiation. Detection reliability is also proven by linear response of the X-ray detector, and the X-ray detection limit is 3 mA.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherWILEY-
dc.titleOrganic X-Ray Image Sensors Using a Medium Bandgap Polymer Donor with Low Dark Current-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1002/eem2.12750-
dc.identifier.scopusid2-s2.0-85192552300-
dc.identifier.wosid001216356900001-
dc.identifier.bibliographicCitationEnergy & Environmental Materials, pp 1 - 8-
dc.citation.titleEnergy & Environmental Materials-
dc.citation.startPage1-
dc.citation.endPage8-
dc.type.docTypeArticle; Early Access-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaMaterials Science-
dc.relation.journalWebOfScienceCategoryMaterials Science, Multidisciplinary-
dc.subject.keywordPlusDETECTORS-
dc.subject.keywordPlusPHOTOCONDUCTORS-
dc.subject.keywordPlusSENSITIVITY-
dc.subject.keywordAuthorlow dark current-
dc.subject.keywordAuthorlow detection limit-
dc.subject.keywordAuthororganic photodetector-
dc.subject.keywordAuthorprintable-
dc.subject.keywordAuthorX-ray-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/10.1002/eem2.12750-
Files in This Item
Appears in
Collections
서울 공과대학 > 서울 유기나노공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jung, In Hwan photo

Jung, In Hwan
COLLEGE OF ENGINEERING (DEPARTMENT OF ORGANIC AND NANO ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE