Cited 0 time in
Data loss recovery for power failure in flash memory storage systems
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jung, Sanghyuk | - |
| dc.contributor.author | Song, Yong Ho | - |
| dc.date.accessioned | 2024-12-20T06:24:06Z | - |
| dc.date.available | 2024-12-20T06:24:06Z | - |
| dc.date.issued | 2015-01 | - |
| dc.identifier.issn | 1383-7621 | - |
| dc.identifier.issn | 1873-6165 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/202624 | - |
| dc.description.abstract | Due to the rapid development of flash memory technology, NAND flash has been widely used as a storage device in portable embedded systems, personal computers, and enterprise systems. However, flash memory is prone to performance degradation due to the long latency in flash program operations and flash erasure operations. One common technique for hiding long program latency is to use a temporal buffer to hold write data. Although DRAM is often used to implement the buffer because of its high performance and low bit cost, it is volatile; thus, that the data may be lost on power failure in the storage system. As a solution to this issue, recent operating systems frequently issue flush commands to force storage devices to permanently move data from the buffer into the non-volatile area. However, the excessive use of flush commands may worsen the write performance of the storage systems. in this paper, we propose two data loss recovery techniques that require fewer write operations to flash memory. These techniques remove unnecessary flash writes by storing storage metadata along with user data simultaneously by utilizing the spare area associated with each data page. (C) 2014 Elsevier B.V. All rights reserved. | - |
| dc.format.extent | 16 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Data loss recovery for power failure in flash memory storage systems | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.sysarc.2014.11.002 | - |
| dc.identifier.scopusid | 2-s2.0-84920119517 | - |
| dc.identifier.wosid | 000348485900002 | - |
| dc.identifier.bibliographicCitation | Journal of Systems Architecture, v.61, no.1, pp 12 - 27 | - |
| dc.citation.title | Journal of Systems Architecture | - |
| dc.citation.volume | 61 | - |
| dc.citation.number | 1 | - |
| dc.citation.startPage | 12 | - |
| dc.citation.endPage | 27 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Computer Science | - |
| dc.relation.journalWebOfScienceCategory | Computer Science, Hardware & Architecture | - |
| dc.relation.journalWebOfScienceCategory | Computer Science, Software Engineering | - |
| dc.subject.keywordPlus | ARCHITECTURE | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordPlus | TRANSLATION | - |
| dc.subject.keywordPlus | MANAGEMENT | - |
| dc.subject.keywordPlus | SCHEME | - |
| dc.subject.keywordPlus | POLICY | - |
| dc.subject.keywordPlus | LAYER | - |
| dc.subject.keywordAuthor | Power failure | - |
| dc.subject.keywordAuthor | Power loss recovery | - |
| dc.subject.keywordAuthor | Storage management | - |
| dc.subject.keywordAuthor | Flash storage system | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S138376211400143X?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
