Cited 0 time in
Long Range Eye Gaze Tracking System for a Large Screen
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Cho, Dong-Chan | - |
| dc.contributor.author | Yap, Wah-Seng | - |
| dc.contributor.author | Lee, HeeKyung | - |
| dc.contributor.author | Lee, Injae | - |
| dc.contributor.author | Kim, Whoi-Yul | - |
| dc.date.accessioned | 2024-12-20T06:24:06Z | - |
| dc.date.available | 2024-12-20T06:24:06Z | - |
| dc.date.issued | 2012-11 | - |
| dc.identifier.issn | 0098-3063 | - |
| dc.identifier.issn | 1558-4127 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/202628 | - |
| dc.description.abstract | Eye gaze tracking system has been widely researched for the replacement of the conventional computer interfaces such as the mouse and keyboard. In this paper, we propose the long range binocular eye gaze tracking system that works from 1.5 m to 2.5 m with allowing a head displacement in depth. The 3D position of the user's eye is obtained from the two wide angle cameras. A high resolution image of the eye is captured using the pan, tilt, and focus controlled narrow angle camera. The angles for maneuvering the pan and tilt motor are calculated by the proposed calibration method based on virtual camera model. The performance of the proposed calibration method is verified in terms of speed and convenience through the experiment. The narrow angle camera keeps tracking the eye while the user moves his head freely. The point-of-gaze (POG) of each eye onto the screen is calculated by using a 2D mapping based gaze estimation technique and the pupil center corneal reflection (PCCR) vector. PCCR vector modification method is applied to overcome the degradation in accuracy with displacements of the head in depth. The final POG is obtained by the average of the two POGs. Experimental results show that the proposed system robustly works for a large screen TV from 1.5 m to 2.5 m distance with displacements of the head in depth (+/- 20 cm) and the average angular error is 0.69 degrees.(1) | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Electrical and Electronics Engineers | - |
| dc.title | Long Range Eye Gaze Tracking System for a Large Screen | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/TCE.2012.6414976 | - |
| dc.identifier.scopusid | 2-s2.0-84873804722 | - |
| dc.identifier.wosid | 000314168700004 | - |
| dc.identifier.bibliographicCitation | IEEE Transactions on Consumer Electronics, v.58, no.4, pp 1119 - 1128 | - |
| dc.citation.title | IEEE Transactions on Consumer Electronics | - |
| dc.citation.volume | 58 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 1119 | - |
| dc.citation.endPage | 1128 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | sci | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Telecommunications | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Telecommunications | - |
| dc.subject.keywordPlus | HEAD | - |
| dc.subject.keywordPlus | CAMERAS | - |
| dc.subject.keywordAuthor | Eye gaze tracking | - |
| dc.subject.keywordAuthor | human computer interaction | - |
| dc.subject.keywordAuthor | gaze estimation | - |
| dc.subject.keywordAuthor | pupil-corneal | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/6414976 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
