Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Measurement of choroidal thickness in normal eyes using 3D OCT-1000 spectral domain optical coherence tomography.

Full metadata record
DC Field Value Language
dc.contributor.authorShin, Joong Won-
dc.contributor.authorShin, Yong Un-
dc.contributor.authorCho, Hee Yoon-
dc.contributor.authorLee, Byung Ro-
dc.date.accessioned2024-12-20T06:25:54Z-
dc.date.available2024-12-20T06:25:54Z-
dc.date.issued2012-08-
dc.identifier.issn1011-8942-
dc.identifier.issn2092-9382-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/202829-
dc.description.abstractTo study choroidal thickness and its topographic profile in normal eyes using 3D OCT-1000 spectral domain optical coherence tomography and the correlation with age and refractive error. Fifty-seven eyes (45 individuals) with no visual complaints or ocular disease underwent horizontal and vertical line scanning using 3D OCT-1000. The definition of choroidal thickness was the vertical distance between the posterior edge of the hyper-reflective retinal pigment epithelium and the choroid/sclera junction. Choroidal thickness was measured in the subfoveal area at 500 μm intervals from the fovea to 2,500 μm in the nasal, temporal, superior, and inferior regions. The spherical equivalent refractive error was measured by autorefractometry. Statistical analysis was used to confirm the correlations of choroidal thickness with age and refraction error. The mean age of the 45 participants (57 eyes) was 45.28 years. Detailed visualization of the choroid for measuring its thickness was possible in 63.3% of eyes. The mean subfoveal choroidal thickness was found to be 270.8 μm (standard deviation [SD], ±51 μm), in horizontal scanning and 275.0 μm (SD, ±49 μm) in vertical scanning. The temporal choroidal thickness was greater than any 500 μm interval in corresponding locations, and there was no significant difference between the superior and inferior choroid as far as 2,000 μm from the fovea. Age and refractive error were associated with subfoveal choroidal thickness in terms of regression (p < 0.05). Choroidal thickness in normal Korean eyes can be measured using 3D OCT-1000 with high resolution line scanning. The topographical profile of choroidal thickness varies depending on its location. Age and refractive error are essential factors for interpretation of choroidal thickness.-
dc.format.extent5-
dc.language영어-
dc.language.isoENG-
dc.publisher대한안과학회-
dc.titleMeasurement of choroidal thickness in normal eyes using 3D OCT-1000 spectral domain optical coherence tomography.-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3341/kjo.2012.26.4.255-
dc.identifier.scopusid2-s2.0-84872018115-
dc.identifier.bibliographicCitationKorean Journal of Ophthalmology, v.26, no.4, pp 255 - 259-
dc.citation.titleKorean Journal of Ophthalmology-
dc.citation.volume26-
dc.citation.number4-
dc.citation.startPage255-
dc.citation.endPage259-
dc.type.docTypeArticle-
dc.identifier.kciidART001684865-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordPlusarticle-
dc.subject.keywordPlusAsian-
dc.subject.keywordPluschoroid-
dc.subject.keywordPlusfemale-
dc.subject.keywordPlushistology-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusmale-
dc.subject.keywordPlusmethodology-
dc.subject.keywordPlusmiddle aged-
dc.subject.keywordPlusoptical coherence tomography-
dc.subject.keywordPlusorgan size-
dc.subject.keywordPlusreference value-
dc.subject.keywordPlusrefraction error-
dc.subject.keywordPlusSouth Korea-
dc.subject.keywordPlusthree dimensional imaging-
dc.subject.keywordPlusAsian Continental Ancestry Group-
dc.subject.keywordPlusChoroid-
dc.subject.keywordPlusFemale-
dc.subject.keywordPlusHumans-
dc.subject.keywordPlusImaging, Three-Dimensional-
dc.subject.keywordPlusMale-
dc.subject.keywordPlusMiddle Aged-
dc.subject.keywordPlusOrgan Size-
dc.subject.keywordPlusReference Values-
dc.subject.keywordPlusRefractive Errors-
dc.subject.keywordPlusRepublic of Korea-
dc.subject.keywordPlusTomography, Optical Coherence-
dc.subject.keywordAuthorChoroidal thickness-
dc.subject.keywordAuthorSpectral domain optical coherence tomography-
dc.identifier.urlhttps://www.ekjo.org/journal/view.php?doi=10.3341/kjo.2012.26.4.255-
Files in This Item
Appears in
Collections
서울 의과대학 > 서울 안과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE