Detailed Information

Cited 5 time in webofscience Cited 5 time in scopus
Metadata Downloads

A method to estimate the absolute ultrasonic nonlinearity parameter from relative measurements

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Jongbeom-
dc.contributor.authorSong, Dong-Gi-
dc.contributor.authorJhang, Kyung-Young-
dc.date.accessioned2021-08-02T15:26:28Z-
dc.date.available2021-08-02T15:26:28Z-
dc.date.created2021-05-12-
dc.date.issued2017-05-
dc.identifier.issn0041-624X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/20346-
dc.description.abstractThe ultrasonic nonlinearity parameter (β) is determined from the particle displacement amplitudes of the fundamental and second-order harmonic components in an ultrasonic wave propagated through a material. This parameter is generally referred to as the absolute parameter. However, measuring the second harmonic component is especially difficult because its amplitude is usually much smaller than those of signals in typical ultrasonic measurements. For this reason, most studies use the relative parameter determined using the measured electric signal amplitudes of the fundamental and second harmonic ultrasonic waves. However, in many occasions, the absolute parameter is needed for a quantitative assessment of material degradation. This study proposes a method to estimate the absolute parameter from a measured relative parameter along with a proportionality constant between normalized absolute and relative parameters. This method is based on the observed fact that the ratio of between normalized relative and absolute parameters is identical after compensating proportionality constant. The method was experimentally validated for Al6061-T6 alloy specimens heat-treated for different aging times. The parameter determined through the proposed method were compared with the absolute parameters which were measured separately. The results show that these two parameters were close to each other within the measurement errors.-
dc.language영어-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.titleA method to estimate the absolute ultrasonic nonlinearity parameter from relative measurements-
dc.typeArticle-
dc.contributor.affiliatedAuthorJhang, Kyung-Young-
dc.identifier.doi10.1016/j.ultras.2017.02.013-
dc.identifier.scopusid2-s2.0-85013880282-
dc.identifier.wosid000399515100023-
dc.identifier.bibliographicCitationULTRASONICS, v.77, pp.197 - 202-
dc.relation.isPartOfULTRASONICS-
dc.citation.titleULTRASONICS-
dc.citation.volume77-
dc.citation.startPage197-
dc.citation.endPage202-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaAcoustics-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryAcoustics-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusALUMINUM-ALLOY-
dc.subject.keywordPlus3RD HARMONICS-
dc.subject.keywordPlusGENERATION-
dc.subject.keywordPlus2ND-
dc.subject.keywordPlusDISLOCATIONS-
dc.subject.keywordAuthorUltrasonic nonlinearity parameter-
dc.subject.keywordAuthorAbsolute parameter-
dc.subject.keywordAuthorRelative parameter-
dc.subject.keywordAuthorAl6061-T6 alloy-
dc.subject.keywordAuthorThermal aging-
dc.identifier.urlhttps://linkinghub.elsevier.com/retrieve/pii/S0041624X16302748-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jhang, Kyung Young photo

Jhang, Kyung Young
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE