Cited 0 time in
A Torque Reference Limiter to Avoid Unstable Region of High-Frequency Signal Injection-Based Sensorless Control
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Hyun-Jun | - |
| dc.contributor.author | Joo, Je-Eok | - |
| dc.contributor.author | Lee, Hak-Jun | - |
| dc.contributor.author | Yoon, Young Doo | - |
| dc.date.accessioned | 2024-12-20T07:47:22Z | - |
| dc.date.available | 2024-12-20T07:47:22Z | - |
| dc.date.issued | 2022-06 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/203602 | - |
| dc.description.abstract | A pulsating high-frequency (HF) signal injection-based sensorless control enables the zero/low-frequency sensorless control. The rotor position is estimated from the induced HF current based on the machine's saliency. So, the control performance may be degraded if the saliency characteristics change due to the magnetic flux-linkage saturation effect. Especially, rotor position estimation may fail due to the loss of saliency, making the sensorless control unstable. This paper analyzes the unstable region of the sensorless control and shows the examination result of the unstable region of permanent-magnet synchronous machines (PMSMs) where the saliency disappears. In addition, a torque reference limiter to avoid the unstable region of sensorless control is proposed in this paper. The unstable region of the sensorless control can be identified using the dynamic inductance, where the inductance is calculated from the measured current and the magnetic flux-linkage saturation model. The proposed torque reference limiter restricts the operating point to avoid the unstable region. The proposed method was verified with an 11 kW IPMSM, and the results proved that the sensorless control fault could be avoided with the proposed method. | - |
| dc.format.extent | 5 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Electrical and Electronics Engineers Inc. | - |
| dc.title | A Torque Reference Limiter to Avoid Unstable Region of High-Frequency Signal Injection-Based Sensorless Control | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/ITEC53557.2022.9813760 | - |
| dc.identifier.scopusid | 2-s2.0-85134691082 | - |
| dc.identifier.wosid | 000848063600119 | - |
| dc.identifier.bibliographicCitation | 2022 IEEE Transportation Electrification Conference and Expo, ITEC 2022, pp 692 - 696 | - |
| dc.citation.title | 2022 IEEE Transportation Electrification Conference and Expo, ITEC 2022 | - |
| dc.citation.startPage | 692 | - |
| dc.citation.endPage | 696 | - |
| dc.type.docType | Proceedings Paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Transportation | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Aerospace | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Transportation Science & Technology | - |
| dc.subject.keywordPlus | Flux linkage | - |
| dc.subject.keywordPlus | Inductance | - |
| dc.subject.keywordPlus | Magnetic flux | - |
| dc.subject.keywordPlus | Permanent magnets | - |
| dc.subject.keywordPlus | Sensorless control | - |
| dc.subject.keywordPlus | Control performance | - |
| dc.subject.keywordPlus | High-frequency current | - |
| dc.subject.keywordPlus | High-frequency signal injection | - |
| dc.subject.keywordPlus | Lower frequencies | - |
| dc.subject.keywordPlus | Machine saliency | - |
| dc.subject.keywordPlus | Magnetic flux linkage | - |
| dc.subject.keywordPlus | Pulsating high-frequency signal injections | - |
| dc.subject.keywordPlus | Rotor position | - |
| dc.subject.keywordPlus | Saturation effects | - |
| dc.subject.keywordPlus | Unstable regions | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/9813760 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.