Cited 0 time in
Comparison of neoatherosclerosis and clinical outcomes between bioabsorbable versus durable polymer drug-eluting stent: Verification by optical coherence tomography analysis
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Cho, Jae Young | - |
| dc.contributor.author | Kook, Hyungdon | - |
| dc.contributor.author | Anvarov, Javoxir | - |
| dc.contributor.author | Makhkamov, Najmiddin | - |
| dc.contributor.author | Cho, Sang -A | - |
| dc.contributor.author | Yu, Cheol Woong | - |
| dc.date.accessioned | 2024-12-20T07:55:39Z | - |
| dc.date.available | 2024-12-20T07:55:39Z | - |
| dc.date.issued | 2022-04 | - |
| dc.identifier.issn | 1897-5593 | - |
| dc.identifier.issn | 1898-018X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/203927 | - |
| dc.description.abstract | Background: Neoatherosclerosis after drug-eluting stent (DES) implantation is known to be related with increased risk of late restenosis and stent thrombosis. Neoatherosclerosis and relevant clinical outcomes between bioabsorbable polymer DES (BP-DES) and second-generation durable polymer DES (DP-DES) were evaluated by optical coherence tomography (OCT) analysis.Methods: A total of 311 patients (319 lesions) undergoing OCT analysis after DES implantation were enrolled and divided into two groups according to stent type (BP-DES [150 patients, 153 lesions] and DP--DES[161 patients, 166 lesions]). Follow-up OCT analysis was performed at least 9 months after index stent implantation. Neoatherosclerosis was defined as presence of thin-cap fibroatheroma, calcified plaque, and lipid plaque. Primary endpoint was the incidence of neoatherosclerosis, and the secondary endpoints were the occurrence of major adverse cardiac events (MACE), defined as a composite of death, myocardial infarction, target lesion revascularization, or stent thrombosis and to find independent predictors of neoatherosclerosis.Results: The incidence of neoatherosclerosis was lower in the BP-DES group than the DP-DES group (5.2% vs. 14.5%, p = 0.008), which was driven by lipid plaque. However, the incidence of MACE did not show statistical difference between the two groups in median 4-year follow-up (3.3% vs. 7.8%, hazard ratio 1.964, 95% confidence interval 0.688-5.611, p = 0.207). Less use of angiotensin converting en- zyme inhibitors/angiotensin II receptor blockade and higher degree of neointimal hyperplasia remained independent predictors of neoatherosclerosis on Cox regression analysis.Conclusions: Patients undergoing BP-DES implantation had lower incidence of neoatherosclerosis than DP-DES, which did not reach statistically better clinical outcomes. (Cardiol J) | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Via Medica | - |
| dc.title | Comparison of neoatherosclerosis and clinical outcomes between bioabsorbable versus durable polymer drug-eluting stent: Verification by optical coherence tomography analysis | - |
| dc.type | Article | - |
| dc.publisher.location | 폴란드 | - |
| dc.identifier.doi | 10.5603/CJ.a2022.0025 | - |
| dc.identifier.scopusid | 2-s2.0-85178889311 | - |
| dc.identifier.wosid | 000934639200001 | - |
| dc.identifier.bibliographicCitation | Cardiology Journal, v.30, no.6, pp 911 - 920 | - |
| dc.citation.title | Cardiology Journal | - |
| dc.citation.volume | 30 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 911 | - |
| dc.citation.endPage | 920 | - |
| dc.type.docType | Article; Early Access | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Cardiovascular System & Cardiology | - |
| dc.relation.journalWebOfScienceCategory | Cardiac & Cardiovascular Systems | - |
| dc.subject.keywordPlus | BARE-METAL | - |
| dc.subject.keywordPlus | BIODEGRADABLE POLYMER | - |
| dc.subject.keywordPlus | CORONARY STENT | - |
| dc.subject.keywordPlus | IMPLANTATION | - |
| dc.subject.keywordPlus | THROMBOSIS | - |
| dc.subject.keywordPlus | METAANALYSIS | - |
| dc.subject.keywordPlus | INDUCTION | - |
| dc.subject.keywordPlus | TRIALS | - |
| dc.subject.keywordAuthor | neointima | - |
| dc.subject.keywordAuthor | coronary restenosis | - |
| dc.subject.keywordAuthor | drug-eluting stents | - |
| dc.subject.keywordAuthor | tomography | - |
| dc.subject.keywordAuthor | optical coherence | - |
| dc.identifier.url | https://journals.viamedica.pl/cardiology_journal/article/view/71808 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
