Detailed Information

Cited 21 time in webofscience Cited 22 time in scopus
Metadata Downloads

Clinical feasibility of brain-computer interface based on steady-state visual evoked potential in patients with locked-in syndrome: Case studies

Full metadata record
DC Field Value Language
dc.contributor.authorHwang, Han-Jeong-
dc.contributor.authorHan, Chang-Hee-
dc.contributor.authorLim, Jeong-Hwan-
dc.contributor.authorKim, Yong-Wook-
dc.contributor.authorChoi, Soo-In-
dc.contributor.authorAn, Kwang-Ok-
dc.contributor.authorLee, Jun-Hak-
dc.contributor.authorCha, Ho-Seung-
dc.contributor.authorKim, Seung Hyun-
dc.contributor.authorIm, Chang-Hwan-
dc.date.accessioned2021-08-02T15:30:52Z-
dc.date.available2021-08-02T15:30:52Z-
dc.date.issued2017-03-
dc.identifier.issn0048-5772-
dc.identifier.issn1469-8986-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/20510-
dc.description.abstractAlthough the feasibility of brain-computer interface (BCI) systems based on steady-state visual evoked potential (SSVEP) has been extensively investigated, only a few studies have evaluated its clinical feasibility in patients with locked-in syndrome (LIS), who are the main targets of BCI technology. The main objective of this case report was to share our experiences of SSVEP-based BCI experiments involving five patients with LIS, thereby providing researchers with useful information that can potentially help them to design BCI experiments for patients with LIS. In our experiments, a four-class online SSVEP-based BCI system was implemented and applied to four of five patients repeatedly on multiple days to investigate its test-retest reliability. In the last experiments with two of the four patients, the practical usability of our BCI system was tested using a questionnaire survey. All five patients showed clear and distinct SSVEP responses at all four fundamental stimulation frequencies (6, 6.66, 7.5, 10 Hz), and responses at harmonic frequencies were also observed in three patients. Mean classification accuracy was 76.99% (chance level=25%). The test-retest reliability experiments demonstrated stable performance of our BCI system over different days even when the initial experimental settings (e.g., electrode configuration, fixation time, visual angle) used in the first experiment were used without significant modifications. Our results suggest that SSVEP-based BCI paradigms might be successfully used to implement clinically feasible BCI systems for severely paralyzed patients.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisherBlackwell Publishing Inc.-
dc.titleClinical feasibility of brain-computer interface based on steady-state visual evoked potential in patients with locked-in syndrome: Case studies-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1111/psyp.12793-
dc.identifier.scopusid2-s2.0-85006150237-
dc.identifier.wosid000395648400012-
dc.identifier.bibliographicCitationPsychophysiology, v.54, no.3, pp 444 - 451-
dc.citation.titlePsychophysiology-
dc.citation.volume54-
dc.citation.number3-
dc.citation.startPage444-
dc.citation.endPage451-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasssci-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassssci-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaPsychology-
dc.relation.journalResearchAreaNeurosciences & Neurology-
dc.relation.journalResearchAreaPhysiology-
dc.relation.journalWebOfScienceCategoryPsychology, Biological-
dc.relation.journalWebOfScienceCategoryNeurosciences-
dc.relation.journalWebOfScienceCategoryPhysiology-
dc.relation.journalWebOfScienceCategoryPsychology-
dc.relation.journalWebOfScienceCategoryPsychology, Experimental-
dc.subject.keywordPlusSSVEP-
dc.subject.keywordPlusBCI-
dc.subject.keywordPlusCOMMUNICATION-
dc.subject.keywordPlusWHEELCHAIR-
dc.subject.keywordAuthorBrain-computer interface (BCI)-
dc.subject.keywordAuthorSteady-state visual evoked potential (SSVEP)-
dc.subject.keywordAuthorEEG-
dc.subject.keywordAuthorClinical feasibility-
dc.subject.keywordAuthorLocked-in syndrome (LIS)-
dc.subject.keywordAuthorAmyotrophic lateral sclerosis (ALS)-
dc.identifier.urlhttps://onlinelibrary.wiley.com/doi/full/10.1111/psyp.12793-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > ETC > 1. Journal Articles
서울 의과대학 > 서울 신경과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Im, Chang Hwan photo

Im, Chang Hwan
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE