Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Simulation study for the energy and position reconstruction performances of the beam monitoring system of Carbon Ion Radiation Therapy using GEANT4

Full metadata record
DC Field Value Language
dc.contributor.authorEo, Yun-
dc.contributor.authorKwon, Na Hye-
dc.contributor.authorBae, Joonsuk-
dc.contributor.authorCheon, Byunggu-
dc.contributor.authorCho, Guk-
dc.contributor.authorChoi, Suyong-
dc.contributor.authorDo, Hyunsuk-
dc.contributor.authorHa, Seungkyu-
dc.contributor.authorHuh, Changgi-
dc.contributor.authorHwang, Kyuyeong-
dc.contributor.authorJang, Haeun-
dc.contributor.authorJang, Seoyun-
dc.contributor.authorJang, Yoonjun-
dc.contributor.authorJeong, Jinryong-
dc.contributor.authorKim, Beomkyu-
dc.contributor.authorKim, Bobae-
dc.contributor.authorKim, Dongwoon-
dc.contributor.authorKim, Sungwon-
dc.contributor.authorKo, Sanghyun-
dc.contributor.authorLee, Hyupwoo-
dc.contributor.authorLee, Hyungjun-
dc.contributor.authorLee, Jason-
dc.contributor.authorLee, Junghyun-
dc.contributor.authorLee, Sehwook-
dc.contributor.authorLee, Woochan-
dc.contributor.authorLee, Yunjae-
dc.contributor.authorLim, Sanghoon-
dc.contributor.authorPark, Hyesung-
dc.contributor.authorRyu, Jaehyeok-
dc.contributor.authorKim, Jin Sung-
dc.contributor.authorRyu, Min Sang-
dc.contributor.authorYoo, Hwidong-
dc.contributor.authorKim, Dong Wook-
dc.contributor.authorKim, Minsuk-
dc.date.accessioned2025-02-25T03:00:17Z-
dc.date.available2025-02-25T03:00:17Z-
dc.date.issued2025-02-
dc.identifier.issn1932-6203-
dc.identifier.issn1932-6203-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/206554-
dc.description.abstractCarbon Ion Radiation Therapy is operated in several countries because of its advantage to have high dose concentration and/or high linear energy transfer (LET). To estimate the beam performance of Carbon Ion Radiation Therapy, we target the 1% energy and 1 mm2 position resolutions of the beam monitoring system. The beam monitoring system consists of a scintillation crystal and fiber hodoscope. The scintillation crystal is 20 × 20 × 120mm3 and its candidates are LYSO, CsI and BGO. The fiber hodoscope is composed of 1 mm thickness scintillation fibers and the fibers are arranged vertically for 2D reconstruction. With GEANT4 simulation, we verify the performance of our beam monitoring system. The energy response of the LYSO and BGO scintillators is linear within ± 2%. The energy resolution of each crystal candidate achieves the goal; LYSO (0.061%), CsI (0.20%) and BGO (0.10%). The position is reconstructed via fiber hodoscope within 5% uncertainty.-
dc.format.extent17-
dc.language영어-
dc.language.isoENG-
dc.publisherPublic Library of Science-
dc.titleSimulation study for the energy and position reconstruction performances of the beam monitoring system of Carbon Ion Radiation Therapy using GEANT4-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1371/journal.pone.0313862-
dc.identifier.scopusid2-s2.0-85216981769-
dc.identifier.wosid001413986400001-
dc.identifier.bibliographicCitationPLoS ONE, v.20, no.2, pp 1 - 17-
dc.citation.titlePLoS ONE-
dc.citation.volume20-
dc.citation.number2-
dc.citation.startPage1-
dc.citation.endPage17-
dc.type.docTypeArticle-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusbismuth germanate-
dc.subject.keywordPlusunclassified drug-
Files in This Item
There are no files associated with this item.
Appears in
Collections
서울 자연과학대학 > 서울 물리학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Cheon, Byung Gu photo

Cheon, Byung Gu
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF PHYSICS)
Read more

Altmetrics

Total Views & Downloads

BROWSE