| dc.description.abstract | This study presents a novel approach to magnetic resonance-mediated radiofrequency ablation (MR-RFA) by utilizing a textile-based wire antenna. The antenna is designed to harvest the electromotive force generated by a circularly polarized radiofrequency birdcage coil, enabling the induction of high temperatures at the needle tip. A highly conductive thread was embroidered on a textile substrate to enhance the specific absorption rate (SAR) and induced temperature. Temperature measurements on agarose phantoms and bovine liver tissues were conducted using a 3 T MRI scanner, with temperature increases visualized via the proton resonance frequency shift technique. Simulation results revealed a nearly tenfold increase in SAR and an induced temperature of up to 82 °C at the RFA needle tip. Clear thermal lesions were observed in agarose phantoms and bovine liver tissues with no MR image distortion, alongside temperature maps showing a 73 °C peak at the needle tip. The proposed wearable design has the potential to enhance patient comfort during live ablation procedures with greater flexibility while providing clearer MRI images without distortion. This wearable system, integrated with an MRI scanner, offers a streamlined alternative to traditional bulky ablation setups, enabling real-time, highly precise therapeutic interventions. | - |
| dc.format.extent | 13 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Institute of Electrical and Electronics Engineers | - |
| dc.title | Performance of Textile-Based Antennas for Magnetic Resonance-Mediated Radiofrequency Ablation at 3 T MRI: An Evaluation in Liver Tissue | - |
| dc.title.alternative | Performance of Textile-Based Antennas for Magnetic Resonance-Mediated Radio Frequency Ablation at 3-T MRI: An Evaluation in Liver Tissue | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/TIM.2025.3545848 | - |
| dc.identifier.scopusid | 2-s2.0-85218882273 | - |
| dc.identifier.wosid | 001445070100021 | - |
| dc.identifier.bibliographicCitation | IEEE Transactions on Instrumentation and Measurement, v.74, pp 1 - 13 | - |
| dc.citation.title | IEEE Transactions on Instrumentation and Measurement | - |
| dc.citation.volume | 74 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 13 | - |
| dc.type.docType | Article in press | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordPlus | RADIOFREQUENCY THERMAL ABLATION | - |
| dc.subject.keywordPlus | IN-VIVO | - |
| dc.subject.keywordPlus | PERCUTANEOUS TREATMENT | - |
| dc.subject.keywordPlus | TECHNICAL SUCCESS | - |
| dc.subject.keywordPlus | RABBIT LIVER | - |
| dc.subject.keywordPlus | TUMORS | - |
| dc.subject.keywordPlus | CARCINOMA | - |
| dc.subject.keywordPlus | GUIDANCE | - |
| dc.subject.keywordPlus | OUTCOMES | - |
| dc.subject.keywordPlus | SITE | - |
| dc.subject.keywordAuthor | Wire | - |
| dc.subject.keywordAuthor | Magnetic resonance imaging | - |
| dc.subject.keywordAuthor | Radio frequency | - |
| dc.subject.keywordAuthor | Coils | - |
| dc.subject.keywordAuthor | Phantoms | - |
| dc.subject.keywordAuthor | Antennas | - |
| dc.subject.keywordAuthor | Liver | - |
| dc.subject.keywordAuthor | Textiles | - |
| dc.subject.keywordAuthor | Imaging | - |
| dc.subject.keywordAuthor | Needles | - |
| dc.subject.keywordAuthor | 3-T | - |
| dc.subject.keywordAuthor | magnetic resonance imaging (MRI) | - |
| dc.subject.keywordAuthor | magnetic resonance-mediated radio frequency ablation (MR-RFA) | - |
| dc.subject.keywordAuthor | radio frequency (RF) birdcage | - |
| dc.subject.keywordAuthor | textile-based wire antenna | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/10904936 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.