Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Localized defect evaluation method based on beam-coupled vibration

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Chanmin-
dc.contributor.authorPark, Semin-
dc.contributor.authorPark, Junhong-
dc.contributor.authorKwak, Yunsang-
dc.date.accessioned2025-04-30T02:00:18Z-
dc.date.available2025-04-30T02:00:18Z-
dc.date.issued2025-07-
dc.identifier.issn0022-460X-
dc.identifier.issn1095-8568-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/207268-
dc.description.abstractThis study develops and validates an innovative method for detecting localized structural defects using beam-coupled local modes, which confine vibration to targeted areas and remain sensitive to changes in structural properties while unaffected by external boundary conditions. The proposed method creates a beam-coupled local mode by attaching a small auxiliary beam to the host structure, allowing for precise defect identification through localized modal analysis. The coupled wavelength and resonance frequency of this mode are measured and used to determine local bending stiffness, which directly reflects the presence and severity of defects. Theoretical modeling leverages Euler-Bernoulli beam theory to predict vibrational characteristics, focusing on the emergence of local modes at specific frequencies when structural properties are altered. Numerical simulations conducted via the finite element method highlight robustness against changes in external boundary stiffness and its sensitivity to localized changes. Experimental validation using beam structures with systematically introduced defects further confirms the effectiveness of the method in accurately quantifying localized stiffness variations. Compared to existing modal-based methods, the proposed method eliminates the need for complex signal processing and expensive experimental setups, making it a practical and cost-effective alternative for structural health monitoring. The ability of the proposed method to remain unaffected by boundary condition variations and its capability to isolate localized defects enhance its applicability for reliable structural integrity assessments across diverse engineering applications.-
dc.format.extent14-
dc.language영어-
dc.language.isoENG-
dc.publisherAcademic Press-
dc.titleLocalized defect evaluation method based on beam-coupled vibration-
dc.typeArticle-
dc.publisher.location영국-
dc.identifier.doi10.1016/j.jsv.2025.119080-
dc.identifier.scopusid2-s2.0-105001484786-
dc.identifier.wosid001461449500001-
dc.identifier.bibliographicCitationJournal of Sound and Vibration, v.607, pp 1 - 14-
dc.citation.titleJournal of Sound and Vibration-
dc.citation.volume607-
dc.citation.startPage1-
dc.citation.endPage14-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaAcoustics-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMechanics-
dc.relation.journalWebOfScienceCategoryAcoustics-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.relation.journalWebOfScienceCategoryMechanics-
dc.subject.keywordPlusDAMAGE DETECTION-
dc.subject.keywordPlusIDENTIFICATION-
dc.subject.keywordPlusDIAGNOSIS-
dc.subject.keywordAuthorVibration-
dc.subject.keywordAuthorMode shape-
dc.subject.keywordAuthorLocal defect-
dc.subject.keywordAuthorStructural health monitoring-
dc.subject.keywordAuthorNon-destructive testing-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0022460X25001543?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jun hong photo

Park, Jun hong
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE