Cited 0 time in
Diffuser-Supported Hyperspectral Near-Infrared Measurement for Sensitivity Enhancement in Analysis of Diverse Thin Sheet Samples
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Jeong, Haeseong | - |
| dc.contributor.author | Cho, Jiwoo | - |
| dc.contributor.author | Kim, Jaejin | - |
| dc.contributor.author | Chung, Hoeil | - |
| dc.date.accessioned | 2025-06-12T06:01:47Z | - |
| dc.date.available | 2025-06-12T06:01:47Z | - |
| dc.date.issued | 2025-05 | - |
| dc.identifier.issn | 0003-2700 | - |
| dc.identifier.issn | 1520-6882 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/207505 | - |
| dc.description.abstract | A diffuser-supported hyperspectral near-infrared (DS-HS-NIR) measurement scheme in which a Teflon plate as a photon diffuser was placed beneath a thin sheet sample for trans-reflectance spectral acquisition was proposed to enhance the peak intensity (sensitivity) of the sample. The scheme was to increase the number of sample-interacting photons by generating diffused photons using a Teflon (diffuser) and directing them toward a spectroscopic sampling area to additionally interact with a sample, increasing the intensity of the subsequent peak. When the weighing paper, plastic gloves, and mesh fabric sheets (thickness: 20-230 mu m) were measured using a conventional scheme without using the diffuser, peaks corresponding to the sheet samples were difficult to recognize; with the diffuser, they were apparent with enhanced intensity. Furthermore, the increased number of sample-interacting photons when using the diffuser was confirmed by a Monte Carlo simulation. Next, to evaluate its real usage, we attempted to determine the crude protein contents in dried laver sheets (thickness: 210-480 mu m). When the diffuser was employed, peaks centered at 1181 and 1461 nm corresponding to the organic constituents of laver sheets were distinct; these peaks were not observed in the measurement without a diffuser. Due to the peaks with enhanced intensity, the determined crude protein contents were well correlated with those based on conventional Kjeldahl analysis. | - |
| dc.format.extent | 9 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | American Chemical Society | - |
| dc.title | Diffuser-Supported Hyperspectral Near-Infrared Measurement for Sensitivity Enhancement in Analysis of Diverse Thin Sheet Samples | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1021/acs.analchem.5c01349 | - |
| dc.identifier.scopusid | 2-s2.0-105005152730 | - |
| dc.identifier.wosid | 001492952600001 | - |
| dc.identifier.bibliographicCitation | Analytical Chemistry, v.97, no.20, pp 10877 - 10885 | - |
| dc.citation.title | Analytical Chemistry | - |
| dc.citation.volume | 97 | - |
| dc.citation.number | 20 | - |
| dc.citation.startPage | 10877 | - |
| dc.citation.endPage | 10885 | - |
| dc.type.docType | Article; Early Access | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.subject.keywordPlus | SPECTROSCOPY | - |
| dc.subject.keywordPlus | MODELS | - |
| dc.identifier.url | https://pubs.acs.org/doi/10.1021/acs.analchem.5c01349 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
