Diffuser-Supported Hyperspectral Near-Infrared Measurement for Sensitivity Enhancement in Analysis of Diverse Thin Sheet Samples

Full metadata record
DC Field Value Language
dc.contributor.authorJeong, Haeseong-
dc.contributor.authorCho, Jiwoo-
dc.contributor.authorKim, Jaejin-
dc.contributor.authorChung, Hoeil-
dc.date.accessioned2025-06-12T06:01:47Z-
dc.date.available2025-06-12T06:01:47Z-
dc.date.issued2025-05-
dc.identifier.issn0003-2700-
dc.identifier.issn1520-6882-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/207505-
dc.description.abstractA diffuser-supported hyperspectral near-infrared (DS-HS-NIR) measurement scheme in which a Teflon plate as a photon diffuser was placed beneath a thin sheet sample for trans-reflectance spectral acquisition was proposed to enhance the peak intensity (sensitivity) of the sample. The scheme was to increase the number of sample-interacting photons by generating diffused photons using a Teflon (diffuser) and directing them toward a spectroscopic sampling area to additionally interact with a sample, increasing the intensity of the subsequent peak. When the weighing paper, plastic gloves, and mesh fabric sheets (thickness: 20-230 mu m) were measured using a conventional scheme without using the diffuser, peaks corresponding to the sheet samples were difficult to recognize; with the diffuser, they were apparent with enhanced intensity. Furthermore, the increased number of sample-interacting photons when using the diffuser was confirmed by a Monte Carlo simulation. Next, to evaluate its real usage, we attempted to determine the crude protein contents in dried laver sheets (thickness: 210-480 mu m). When the diffuser was employed, peaks centered at 1181 and 1461 nm corresponding to the organic constituents of laver sheets were distinct; these peaks were not observed in the measurement without a diffuser. Due to the peaks with enhanced intensity, the determined crude protein contents were well correlated with those based on conventional Kjeldahl analysis.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisherAmerican Chemical Society-
dc.titleDiffuser-Supported Hyperspectral Near-Infrared Measurement for Sensitivity Enhancement in Analysis of Diverse Thin Sheet Samples-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1021/acs.analchem.5c01349-
dc.identifier.scopusid2-s2.0-105005152730-
dc.identifier.wosid001492952600001-
dc.identifier.bibliographicCitationAnalytical Chemistry, v.97, no.20, pp 10877 - 10885-
dc.citation.titleAnalytical Chemistry-
dc.citation.volume97-
dc.citation.number20-
dc.citation.startPage10877-
dc.citation.endPage10885-
dc.type.docTypeArticle; Early Access-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.subject.keywordPlusSPECTROSCOPY-
dc.subject.keywordPlusMODELS-
dc.identifier.urlhttps://pubs.acs.org/doi/10.1021/acs.analchem.5c01349-
Files in This Item
Go to Link
Appears in
Collections
서울 자연과학대학 > 서울 화학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Hoeil photo

Chung, Hoeil
COLLEGE OF NATURAL SCIENCES (DEPARTMENT OF CHEMISTRY)
Read more

Altmetrics

Total Views & Downloads

BROWSE