Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

IoMT-Enabled Smart-Cap-Powered Ultrawideband Brain Implant for Multichannel Epilepsy Monitoring Applications

Full metadata record
DC Field Value Language
dc.contributor.authorZada, Muhammad-
dc.contributor.authorShah, Izaz Ali-
dc.contributor.authorBasir, Abdul-
dc.contributor.authorYoo, Hyoungsuk-
dc.date.accessioned2025-06-12T06:01:56Z-
dc.date.available2025-06-12T06:01:56Z-
dc.date.issued2025-06-
dc.identifier.issn2372-2541-
dc.identifier.issn2327-4662-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/207524-
dc.description.abstractMultichannel neural monitoring systems are crucial in the accurate diagnosis and treatment of epilepsy by continuously recording neural activity, allowing precise identification of epileptic zones. These systems demand an ultrawideband (UWB) antenna with wireless power reception capability to facilitate high-data-rate communication and battery-free operation for the development of compact and long-lasting neural devices. This articel introduces a compact ( $9\times 11\times 0$ .25 mm3) battery-free implantable UWB system with an integrated rectifier for multichannel epilepsy monitoring, wirelessly powered by a novel 2.4 GHz smart cap-based transmitter (Tx) antenna. Extensive simulations and measurements are conducted to analyze the system's performance. The implantable system exhibits a measured ultrawide bandwidth of 6.8 GHz (1.2-8 GHz) with peak gain values of -16.5, -23, and -24.1 dBi at 2.4, 4.8, and 5.8 GHz, respectively. The proposed wearable smart cap-based Tx antenna efficiently transfers power to the UWB implant system in various scenarios, including lateral and rotational misalignments, achieving a measured transmission coefficient $(|S_{21}|)$ of -20.06 dB at a 15 mm distance while ensuring user comfort and mobility. Moreover, the compact rectifying circuit achieves a maximum conversion efficiency of 78.4% at a low input power of 6 dBm across a 2 k $\Omega $ load. In addition, the safety of the system was validated using a realistic human head model to ensure compliance with the IEEE specific absorption rate limits. The features and performance metrics demonstrate that the proposed UWB implant system, powered by a wearable smart cap, offers a promising solution for safe, continuous, and battery-free multichannel epilepsy monitoring applications.-
dc.format.extent15-
dc.language영어-
dc.language.isoENG-
dc.publisherInstitute of Electrical and Electronics Engineers Inc.-
dc.titleIoMT-Enabled Smart-Cap-Powered Ultrawideband Brain Implant for Multichannel Epilepsy Monitoring Applications-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1109/JIOT.2025.3535223-
dc.identifier.scopusid2-s2.0-85216868014-
dc.identifier.wosid001492163000049-
dc.identifier.bibliographicCitationIEEE Internet of Things Journal, v.12, no.11, pp 17051 - 17065-
dc.citation.titleIEEE Internet of Things Journal-
dc.citation.volume12-
dc.citation.number11-
dc.citation.startPage17051-
dc.citation.endPage17065-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaTelecommunications-
dc.relation.journalWebOfScienceCategoryComputer Science, Information Systems-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryTelecommunications-
dc.subject.keywordPlusSUBDURAL ELECTRODES-
dc.subject.keywordPlusTRANSFER SYSTEM-
dc.subject.keywordPlusWIRELESS-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusANTENNA-
dc.subject.keywordPlusSAFETY-
dc.subject.keywordPlusTELEMETRY-
dc.subject.keywordPlusRECTENNA-
dc.subject.keywordAuthorMonitoring-
dc.subject.keywordAuthorWireless communication-
dc.subject.keywordAuthorEpilepsy-
dc.subject.keywordAuthorWireless sensor networks-
dc.subject.keywordAuthorUltra wideband antennas-
dc.subject.keywordAuthorRecording-
dc.subject.keywordAuthorTransmitting antennas-
dc.subject.keywordAuthorSubstrates-
dc.subject.keywordAuthorUplink-
dc.subject.keywordAuthorRectifiers-
dc.subject.keywordAuthorEpilepsy monitoring-
dc.subject.keywordAuthorInternet of Medical Things (IoMT)-
dc.subject.keywordAuthorneural activity tracking-
dc.subject.keywordAuthorsmart cap-
dc.subject.keywordAuthorultrawideband (UWB)-
dc.subject.keywordAuthorwireless power transfer (WPT)-
dc.identifier.urlhttps://ieeexplore.ieee.org/document/10855595-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > ETC > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoo, Hyoungsuk photo

Yoo, Hyoungsuk
COLLEGE OF ENGINEERING (서울 바이오메디컬공학전공)
Read more

Altmetrics

Total Views & Downloads

BROWSE