Cited 0 time in
Power Loss Analysis of Full-Bridge LLC Resonant Converter Using Enhanced Time Domain Analysis Method
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Keon-Hee | - |
| dc.contributor.author | Park, Su-Seong | - |
| dc.contributor.author | Lee, Dong-Geun | - |
| dc.contributor.author | Kim, Rae-Young | - |
| dc.date.accessioned | 2025-08-08T06:30:24Z | - |
| dc.date.available | 2025-08-08T06:30:24Z | - |
| dc.date.issued | 2025-07 | - |
| dc.identifier.issn | 1975-8359 | - |
| dc.identifier.issn | 2287-4364 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/208420 | - |
| dc.description.abstract | This paper proposes a method for analyzing power loss in a full-bridge LLC resonant converter based on the enhanced Time-Domain Analysis (TDA) technique. The proposed enhanced TDA method demonstrates that the power loss in an LLC resonant converter can be expressed through a complete equation. The necessary initial values are represented in equations, showing a deviation of less than 5% compared to simulation results. Furthermore, based on an 8.4kW full-bridge LLC resonant converter prototype, the proposed method and experimental values are compared in terms of efficiency across different loads, with a maximum error of 1.7% under light loads, while exhibiting highly similar values in other regions. | - |
| dc.format.extent | 11 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 대한전기학회 | - |
| dc.title | Power Loss Analysis of Full-Bridge LLC Resonant Converter Using Enhanced Time Domain Analysis Method | - |
| dc.title.alternative | 향상된 Time Domain Analysis 기법을 이용한 Full-Bridge LLC 공진형 컨버터의 전력 손실 해석 | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.5370/KIEE.2025.74.7.1237 | - |
| dc.identifier.scopusid | 2-s2.0-105011243812 | - |
| dc.identifier.bibliographicCitation | 전기학회논문지, v.74, no.7, pp 1237 - 1247 | - |
| dc.citation.title | 전기학회논문지 | - |
| dc.citation.volume | 74 | - |
| dc.citation.number | 7 | - |
| dc.citation.startPage | 1237 | - |
| dc.citation.endPage | 1247 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART003220431 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordPlus | Electric load loss | - |
| dc.subject.keywordPlus | Power converters | - |
| dc.subject.keywordPlus | Resonant converters | - |
| dc.subject.keywordPlus | Time division multiple access | - |
| dc.subject.keywordAuthor | LLC Resonant Converter | - |
| dc.subject.keywordAuthor | Power Loss Analysis | - |
| dc.subject.keywordAuthor | TDA method | - |
| dc.subject.keywordAuthor | WBG semiconductor | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE12277521&language=ko_KR&hasTopBanner=true | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.