Optimization of a cylindrical heatsink with L-shaped fins to minimize thermal resistance variation by installation angle
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Song, Gihyun | - |
| dc.contributor.author | Nam, Hak-Ho | - |
| dc.contributor.author | Heo, Seungmin | - |
| dc.contributor.author | Yook, Se-Jin | - |
| dc.date.accessioned | 2025-08-20T02:30:24Z | - |
| dc.date.available | 2025-08-20T02:30:24Z | - |
| dc.date.issued | 2025-04 | - |
| dc.identifier.issn | 2214-157X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/208550 | - |
| dc.description.abstract | Light Emitting Diode (LED) lighting can be installed at various angles depending on user preferences. However, the cooling performance of heatsinks may decrease with changes in installation angle, potentially affecting the lifespan of LED lighting. This study considered L-shaped fins on a cylindrical base in an effort to minimize variations in thermal resistance with changes in installation angle while reducing the heatsink mass. Thermal resistance was analyzed based on the area removed from rectangular fins to form L-shaped fins. The heatsink's thermal resistance was predicted across a range of installation angles through numerical analysis using ANSYS FLUENT, and the accuracy of these predictions was validated experimentally. By varying the fin deletion area, fin count, and cylindrical base radius, the ranges of porosity factor and finning factor were determined as 0.7054 ≤ φ ≤ 0.7494 and 2.1069 ≤ ψ ≤ 3.9874, respectively. With the heatsink installation angle varying from 0° to 180°, the rate of change in thermal resistance for a cylindrical heatsink with rectangular fins (without a deletion area) was large, reaching 24 %, while that for a cylindrical heatsink with L-shaped fins was significantly reduced, staying within 10 %. A correlation equation to estimate the thermal resistance of an L-finned cylindrical heatsink was proposed, predicting thermal resistance with an error margin of up to 15 %. The cylindrical heatsink with L-shaped fins developed in this study is expected to be applicable in various LED lighting systems requiring both reduced heatsink mass and minimal thermal resistance variation with changes in installation angle. | - |
| dc.format.extent | 14 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Optimization of a cylindrical heatsink with L-shaped fins to minimize thermal resistance variation by installation angle | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1016/j.csite.2025.105860 | - |
| dc.identifier.scopusid | 2-s2.0-85217968893 | - |
| dc.identifier.wosid | 001432316800001 | - |
| dc.identifier.bibliographicCitation | Case Studies in Thermal Engineering, v.68, pp 1 - 14 | - |
| dc.citation.title | Case Studies in Thermal Engineering | - |
| dc.citation.volume | 68 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 14 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Thermodynamics | - |
| dc.relation.journalWebOfScienceCategory | Thermodynamics | - |
| dc.subject.keywordPlus | NATURAL-CONVECTION | - |
| dc.subject.keywordPlus | JUNCTION TEMPERATURE | - |
| dc.subject.keywordPlus | PIN FIN | - |
| dc.subject.keywordPlus | SINK | - |
| dc.subject.keywordPlus | PERFORMANCE | - |
| dc.subject.keywordPlus | NANOFLUID | - |
| dc.subject.keywordPlus | DESIGN | - |
| dc.subject.keywordPlus | FLOW | - |
| dc.subject.keywordAuthor | Cylindrical base | - |
| dc.subject.keywordAuthor | Heat dissipation | - |
| dc.subject.keywordAuthor | Heatsink | - |
| dc.subject.keywordAuthor | LED lighting | - |
| dc.subject.keywordAuthor | Natural convection | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S2214157X25001200?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.