Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Dose coefficients for ICRP pediatric mesh-type reference computational phantoms under idealized external electron exposures

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorShin, Bangho-
dc.contributor.authorMoon, Sungho-
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorBolch, Wesley E.-
dc.date.accessioned2025-09-11T07:00:30Z-
dc.date.available2025-09-11T07:00:30Z-
dc.date.issued2025-12-
dc.identifier.issn1738-5733-
dc.identifier.issn2234-358X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/208723-
dc.description.abstractIn the present study, a comprehensive dataset of dose coefficients for idealized external electron exposures has been established using the newly released ICRP-156 pediatric mesh-type reference computational phantoms (MRCPs) in conjunction with the Geant4 Monte Carlo radiation transport code. The dataset comprises organ/tissue-averaged absorbed dose coefficients for the 29 target organs and tissues which contribute to the effective dose, as well as effective dose coefficients, spanning three idealized, unidirectional, whole body irradiation geometries—antero-posterior (AP), postero-anterior (PA), and isotropic (ISO)—across 49 discrete electron energies from 10 keV to 10 GeV. Comparisons with the ICRP-145 adult MRCPs revealed significant age-dependent variations, with effective dose coefficients differing by up to ∼38 times (5 years, PA, 50 keV), primarily due to variations in organ/tissue depths across different ages. Further comparisons with the ICRP-143 pediatric voxel-type reference computational phantoms (VRCPs) showed substantial differences below 10 MeV, with effective dose coefficients differing by up to four orders of magnitude, largely attributable to the inclusion of the thin skin target layer in the pediatric MRCPs. The findings of the present study are expected to serve as a valuable resource for optimizing radiological protection strategies for the pediatric population.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisher한국원자력학회-
dc.titleDose coefficients for ICRP pediatric mesh-type reference computational phantoms under idealized external electron exposures-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.1016/j.net.2025.103852-
dc.identifier.scopusid2-s2.0-105013640991-
dc.identifier.wosid001560951300001-
dc.identifier.bibliographicCitationNuclear Engineering and Technology, v.57, no.12, pp 1 - 9-
dc.citation.titleNuclear Engineering and Technology-
dc.citation.volume57-
dc.citation.number12-
dc.citation.startPage1-
dc.citation.endPage9-
dc.type.docTypeArticle-
dc.identifier.kciidART003243414-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordAuthorDose Coefficients-
dc.subject.keywordAuthorExternal Electron Exposures-
dc.subject.keywordAuthorIcrp Reference Phantoms-
dc.subject.keywordAuthorMesh-type-
dc.subject.keywordAuthorMonte Carlo Simulation-
dc.subject.keywordAuthorPediatric Phantoms-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573325004206?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE