Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

시뮬레이션을 이용한 신축 어린이집의 플러쉬아웃 최적화에 관한 연구

Full metadata record
DC Field Value Language
dc.contributor.author이기용-
dc.contributor.author박준석-
dc.date.accessioned2025-10-28T01:00:08Z-
dc.date.available2025-10-28T01:00:08Z-
dc.date.issued2025-08-
dc.identifier.issn1976-6483-
dc.identifier.issn2586-0666-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/208986-
dc.description.abstractFormaldehyde and volatile organic compounds (VOCs) emitted from finishing materials and paints in newly constructed buildings can contribute to sick building syndrome, posing greater health risks to children with underdeveloped immune systems. This study employed the indoor air quality simulation tool CONTAMW to evaluate flush-out effect for formaldehyde and toluene in a nursery room of a newly built daycare center. The simulation results showed that HCHO concentrations were reduced by 10–24%, and toluene by 48.0–78.7%, depending on the flush-out conditions. Moreover, extended flush-out periods with lower air change rates were more effective in reducing pollutant concentrations. These findings offer insights into effective ventilation strategies for preventing symptoms of sick building syndrome and are expected to serve as foundational data for managing indoor air quality in newly built daycare centers, which are not yet subject to mandatory measurement.-
dc.format.extent10-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국건축친환경설비학회-
dc.title시뮬레이션을 이용한 신축 어린이집의 플러쉬아웃 최적화에 관한 연구-
dc.title.alternativeOptimizing Flush-Out Processes for a Newly Built Daycare Centers Using Simulation-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.22696/jkiaebs.20250014-
dc.identifier.bibliographicCitation한국건축친환경설비학회 논문집, v.19, no.4, pp 160 - 169-
dc.citation.title한국건축친환경설비학회 논문집-
dc.citation.volume19-
dc.citation.number4-
dc.citation.startPage160-
dc.citation.endPage169-
dc.type.docTypeY-
dc.identifier.kciidART003238978-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor플러쉬아웃-
dc.subject.keywordAuthor신축 어린이집-
dc.subject.keywordAuthor폼알데하이드-
dc.subject.keywordAuthor휘발성유기화합물-
dc.subject.keywordAuthor새집증후군-
dc.subject.keywordAuthorFlush out-
dc.subject.keywordAuthorNewly built daycare center-
dc.subject.keywordAuthorFormaldehyde-
dc.subject.keywordAuthorVOCs-
dc.subject.keywordAuthorSick building syndrome-
dc.identifier.urlhttps://www.jkiaebs.org/articles/article/ZdM5/#Information-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jun Seok photo

Park, Jun Seok
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE