Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparing 1-L and 2-L Polyethylene Glycol with Ascorbic Acid for Small Bowel Capsule Endoscopy: A Randomized Controlled Trialopen access

Authors
Oh, Chang KyoLee, Sang PyoLee, Jae GonYang, Young JooSeo, Seung InBang, Chang SeokKim, Yu JinShin, Woon GeonKim, Jin BaeJang, Hyun JooKae, Sea HyubBaik, Gwang Ho-Hallym Gastrointestinal Study Group
Issue Date
Jan-2025
Publisher
거트앤리버 소화기연관학회협의회
Keywords
Capsule endoscopes; Video capsule endoscopes; Bowel preparation solutions; Polyethylene glycols
Citation
Gut and Liver, v.19, no.1, pp 87 - 94
Pages
8
Indexed
SCIE
SCOPUS
KCI
Journal Title
Gut and Liver
Volume
19
Number
1
Start Page
87
End Page
94
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/209152
DOI
10.5009/gnl240216
ISSN
1976-2283
2005-1212
Abstract
Background/Aims: Small bowel capsule endoscopy (SBCE) has become the standard for initial evaluation in the diagnosis of small bowel lesions. Although optimal visualization of the mucosa is important, patients experience difficulty in consuming a large volume of bowel preparation agents. This study aimed to compare the efficacy and safety of 1-L polyethylene glycol (PEG) with ascorbic acid (AA) and 2-L PEG with AA. Methods: In this prospective, multicenter, non-inferiority study, patients who received SBCE were randomly assigned to consume 1-L PEG with AA or 2-L PEG with AA for small bowel preparation. The primary outcome was adequate small bowel visibility quality (SBVQ). The secondary outcomes included diagnostic yield, cecal complete rate, and adverse events. Results: One hundred and forty patients were enrolled in this study, 70 patients per group. In the per-protocol analysis, there were no significant differences in the adequate SBVQ rate (94.0% vs 94.3%; risk difference, –0.3; 95% confidence interval, –8.1 to 7.6; p=1.000), diagnostic yield rate (49.3% vs 48.6%, p=0.936), or cecal complete rate (88.1% vs 92.9%, p=0.338) between the 1-L PEG with AA group and 2-L PEG with AA group. The incidence of adverse events did not differ significantly between the groups (12.9% vs 11.9%, p=0.871). Conclusions: One liter-PEG with AA is not inferior to 2-L PEG with AA in terms of adequate SBVQ for SBCE. One liter-PEG with AA can be recommended as the standard method for bowel cleansing for SBCE.
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jae Gon photo

Lee, Jae Gon
서울 의과대학 (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE