Cited 0 time in
Programmable FPGA-based TDLAS-WMS hygrometer (PFTWH) for broad-range water vapour detection: Quantitative assessment of digital lock-in amplifier (DLIA) performance via integrated WMS system (I-WMS)
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Choi, Minyoung | - |
| dc.contributor.author | Cho, Gyuwon | - |
| dc.contributor.author | Hwang, Seyeon | - |
| dc.contributor.author | Lee, Jinwoo | - |
| dc.contributor.author | Kim, Yangmo | - |
| dc.contributor.author | Kim, Jeongmin | - |
| dc.contributor.author | Kim, Kyunghoon | - |
| dc.contributor.author | So, Hongyun | - |
| dc.contributor.author | Choi, Sun | - |
| dc.date.accessioned | 2025-11-21T05:30:25Z | - |
| dc.date.available | 2025-11-21T05:30:25Z | - |
| dc.date.issued | 2026-02 | - |
| dc.identifier.issn | 0925-4005 | - |
| dc.identifier.issn | 1873-3077 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/209243 | - |
| dc.description.abstract | This study demonstrates the capability of wavelength modulation spectroscopy (WMS) based on tunable diode laser absorption spectroscopy (TDLAS) using a hand-held field-programmable gate array (FPGA) system. Programmable FPGA-based TDLAS-WMS hygrometer (PFTWH) enables measurement of water vapour concentrations over a broad range (70-5800 ppm) for applications in climate science. This system incorporates a customdesigned digital lock-in amplifier (DLIA), optimized for water vapour detection. For the DLIA, a 100 Hz cut-off frequency and a finite impulse response filter with a windowed-Hamming design and a 200-tap coefficient were used. The PFTWH demonstrated simultaneous processing capability of 1 f and 2 f signals by programming the DLIA on a commercial FPGA board. To quantitatively evaluate DLIA performance, we introduced an integrated WMS system that enables parallel operation of a commercial FPGA-based TDLAS-WMS hygrometer (CFTWH), the PFTWH, and direct TDLAS (dTDLAS). The 1 f and 2 f signals are extracted from both the CFTWH and PFTWH, while the dTDLAS provides reference concentration information for performance assessment. The linearity and accuracy of the designed PFTWH were validated by comparison with the CFTWH. Additionally, long-term measurements of water vapour concentrations across the broad range (70-5800 ppm) were successfully performed with a time resolution of 0.1 s, maintaining stable performance over 1000 s with 30 s averaging. Furthermore, both PFTWH and CFTWH were demonstrated to meet uncertainty, accuracy, and precision requirements for airborne measurement. | - |
| dc.format.extent | 17 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Elsevier BV | - |
| dc.title | Programmable FPGA-based TDLAS-WMS hygrometer (PFTWH) for broad-range water vapour detection: Quantitative assessment of digital lock-in amplifier (DLIA) performance via integrated WMS system (I-WMS) | - |
| dc.type | Article | - |
| dc.publisher.location | 스위스 | - |
| dc.identifier.doi | 10.1016/j.snb.2025.138930 | - |
| dc.identifier.scopusid | 2-s2.0-105019313656 | - |
| dc.identifier.wosid | 001600315400006 | - |
| dc.identifier.bibliographicCitation | Sensors and Actuators, B: Chemical, v.448, pp 1 - 17 | - |
| dc.citation.title | Sensors and Actuators, B: Chemical | - |
| dc.citation.volume | 448 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 17 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Chemistry | - |
| dc.relation.journalResearchArea | Electrochemistry | - |
| dc.relation.journalResearchArea | Instruments & Instrumentation | - |
| dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
| dc.relation.journalWebOfScienceCategory | Electrochemistry | - |
| dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
| dc.subject.keywordPlus | WAVELENGTH MODULATION SPECTROSCOPY | - |
| dc.subject.keywordPlus | DIODE-LASER | - |
| dc.subject.keywordPlus | MU-M | - |
| dc.subject.keywordPlus | ABSORPTION-SPECTRUM | - |
| dc.subject.keywordPlus | SENSOR | - |
| dc.subject.keywordPlus | DESIGN | - |
| dc.subject.keywordPlus | SPECTROMETER | - |
| dc.subject.keywordPlus | CALIBRATION | - |
| dc.subject.keywordPlus | VALIDATION | - |
| dc.subject.keywordPlus | ABSORBENCY | - |
| dc.subject.keywordAuthor | Hygrometer | - |
| dc.subject.keywordAuthor | DLIA (Digital Lock-In Amplifier) | - |
| dc.subject.keywordAuthor | FPGA (Field-Programmable Gate Array) | - |
| dc.subject.keywordAuthor | Water vapour sensing | - |
| dc.subject.keywordAuthor | TDLAS(Tunable diode laser absorption spectroscopy) | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S092540052501706X?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.