Tactile Threshold Reduction Through Angle-Steered Focused Ultrasound Stimulation Using Capacitive Micromachined Ultrasound Transducer (CMUT)
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kim, Min-chul | - |
| dc.contributor.author | Cho, Youngjin | - |
| dc.contributor.author | Kim, Hyunsu | - |
| dc.contributor.author | Park, Kwan Kyu | - |
| dc.date.accessioned | 2025-12-02T02:30:28Z | - |
| dc.date.available | 2025-12-02T02:30:28Z | - |
| dc.date.issued | 2025-10 | - |
| dc.identifier.issn | 1948-5719 | - |
| dc.identifier.issn | 1948-5727 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/209427 | - |
| dc.description.abstract | This work presents the design, fabrication, and characterization of a Capacitive Micromachined Ultrasonic Transducer (CMUT) for reducing tactile thresholds through angle-steered focused ultrasound stimulation. The device was fabricated using a double oxidation process to achieve a high pull-in voltage and stable operation. A 20-channel annular array was designed with field programmable gate array (FPGA)-based pulser control, enabling phase modulation to generate focused ultrasound at multiple depths. The designed pressure sensitivity was 10.4 kPa/V at 5 MHz, while the measured surface sensitivity ranged from 4 to 7 kPa/V due to fabrication variation. On-axis pressures were measured at focal depths from 2 to 15 mm, and the results were compared with simulations using effective aperture compensation to account for hydrophone acceptance angle. Psychophysical experiments presented that tactile thresholds were lower when the finger pulp surface was aligned with the beam axis than when perpendicular, indicating that beam orientation and contact area play a critical role in perception. These results provide key insights for optimizing ultrasound-based tactile interfaces. | - |
| dc.format.extent | 4 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.title | Tactile Threshold Reduction Through Angle-Steered Focused Ultrasound Stimulation Using Capacitive Micromachined Ultrasound Transducer (CMUT) | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1109/IUS62464.2025.11201848 | - |
| dc.identifier.scopusid | 2-s2.0-105021832022 | - |
| dc.identifier.bibliographicCitation | IEEE International Ultrasonics Symposium, IUS, pp 1 - 4 | - |
| dc.citation.title | IEEE International Ultrasonics Symposium, IUS | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 4 | - |
| dc.type.docType | Conference paper | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.subject.keywordPlus | Actuators | - |
| dc.subject.keywordPlus | Display devices | - |
| dc.subject.keywordPlus | Fabrication | - |
| dc.subject.keywordPlus | Solid-state sensors | - |
| dc.subject.keywordPlus | Tactile sensors | - |
| dc.subject.keywordPlus | Ultrasonic scattering | - |
| dc.subject.keywordPlus | Ultrasonic transducers | - |
| dc.subject.keywordPlus | Ultrasonics | - |
| dc.subject.keywordAuthor | CMUT | - |
| dc.subject.keywordAuthor | ultrasound tactile | - |
| dc.subject.keywordAuthor | tactile threshold | - |
| dc.subject.keywordAuthor | focused ultrasound | - |
| dc.subject.keywordAuthor | FPGA | - |
| dc.subject.keywordAuthor | annular array | - |
| dc.subject.keywordAuthor | tactile display | - |
| dc.identifier.url | https://ieeexplore.ieee.org/document/11201848 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.