Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Implication of ICRP pediatric reference voxel phantoms on dose assessment of patients in radioiodine therapy

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Soo Min-
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorChoi, Ji Won-
dc.contributor.authorMin, Chul Hee-
dc.contributor.authorKo, Seulki-
dc.contributor.authorShin, Bangho-
dc.contributor.authorKim, Chan Hyeong-
dc.contributor.authorYeom, Yeon Soo-
dc.date.accessioned2025-12-10T06:30:44Z-
dc.date.available2025-12-10T06:30:44Z-
dc.date.issued2024-07-
dc.identifier.issn1738-5733-
dc.identifier.issn2234-358X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/209681-
dc.description.abstractTo investigate the impact of the recently released pediatric reference voxel phantoms (0-, 1-, 5-, 10-, 15-year-old males and females) of the International Commission on Radiological Protection (ICRP) on organ dose estimates for radioactive iodine (RAI) treatment in pediatric patients, we calculated and analyzed pediatric-specific iodine-131 S values (rT ← thyroid) for the 30 radiosensitive organs by conducting Monte Carlo simulations using the Geant4. The gender dependency in the S values was frequently seen for the 15-year-old phantoms with higher S values of female than male. In addition, the age dependency in the S values was observed for most target organs; that is, the S values tend to decrease for older ages (e.g., ∼120 times for the gonads between the adult and newborn) due mainly to the inter-organ distances generally longer for older ages. Moreover, we observed that the iodine-131 S values tend to be significantly greater by up to ∼145.5 times than those of the stylized phantoms that have been widely used for organ dose estimates of pediatric RAI patients. We believe that the pediatric-specific iodine-131 S values (rT ← thyroid) of the ICRP pediatric reference voxel phantoms should be beneficial to improve the dosimetry of pediatric RAI patients.-
dc.format.extent11-
dc.language영어-
dc.language.isoENG-
dc.publisher한국원자력학회-
dc.titleImplication of ICRP pediatric reference voxel phantoms on dose assessment of patients in radioiodine therapy-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.1016/j.net.2024.01.033-
dc.identifier.scopusid2-s2.0-85194460787-
dc.identifier.wosid001249223700006-
dc.identifier.bibliographicCitationNuclear Engineering and Technology, v.56, no.6, pp 2247 - 2257-
dc.citation.titleNuclear Engineering and Technology-
dc.citation.volume56-
dc.citation.number6-
dc.citation.startPage2247-
dc.citation.endPage2257-
dc.type.docTypeArticle-
dc.identifier.kciidART003085890-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordAuthorIodine-131-
dc.subject.keywordAuthorS values-
dc.subject.keywordAuthorICRP pediatric reference phantoms-
dc.subject.keywordAuthorMonte Carlo simulation-
dc.subject.keywordAuthorPediatric patients-
dc.subject.keywordAuthorInternal dosimetry-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573324000354?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE