Cited 0 time in
Implication of ICRP pediatric reference voxel phantoms on dose assessment of patients in radioiodine therapy
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Lee, Soo Min | - |
| dc.contributor.author | Choi, Chansoo | - |
| dc.contributor.author | Choi, Ji Won | - |
| dc.contributor.author | Min, Chul Hee | - |
| dc.contributor.author | Ko, Seulki | - |
| dc.contributor.author | Shin, Bangho | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.contributor.author | Yeom, Yeon Soo | - |
| dc.date.accessioned | 2025-12-10T06:30:44Z | - |
| dc.date.available | 2025-12-10T06:30:44Z | - |
| dc.date.issued | 2024-07 | - |
| dc.identifier.issn | 1738-5733 | - |
| dc.identifier.issn | 2234-358X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/209681 | - |
| dc.description.abstract | To investigate the impact of the recently released pediatric reference voxel phantoms (0-, 1-, 5-, 10-, 15-year-old males and females) of the International Commission on Radiological Protection (ICRP) on organ dose estimates for radioactive iodine (RAI) treatment in pediatric patients, we calculated and analyzed pediatric-specific iodine-131 S values (rT ← thyroid) for the 30 radiosensitive organs by conducting Monte Carlo simulations using the Geant4. The gender dependency in the S values was frequently seen for the 15-year-old phantoms with higher S values of female than male. In addition, the age dependency in the S values was observed for most target organs; that is, the S values tend to decrease for older ages (e.g., ∼120 times for the gonads between the adult and newborn) due mainly to the inter-organ distances generally longer for older ages. Moreover, we observed that the iodine-131 S values tend to be significantly greater by up to ∼145.5 times than those of the stylized phantoms that have been widely used for organ dose estimates of pediatric RAI patients. We believe that the pediatric-specific iodine-131 S values (rT ← thyroid) of the ICRP pediatric reference voxel phantoms should be beneficial to improve the dosimetry of pediatric RAI patients. | - |
| dc.format.extent | 11 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국원자력학회 | - |
| dc.title | Implication of ICRP pediatric reference voxel phantoms on dose assessment of patients in radioiodine therapy | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1016/j.net.2024.01.033 | - |
| dc.identifier.scopusid | 2-s2.0-85194460787 | - |
| dc.identifier.wosid | 001249223700006 | - |
| dc.identifier.bibliographicCitation | Nuclear Engineering and Technology, v.56, no.6, pp 2247 - 2257 | - |
| dc.citation.title | Nuclear Engineering and Technology | - |
| dc.citation.volume | 56 | - |
| dc.citation.number | 6 | - |
| dc.citation.startPage | 2247 | - |
| dc.citation.endPage | 2257 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART003085890 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordAuthor | Iodine-131 | - |
| dc.subject.keywordAuthor | S values | - |
| dc.subject.keywordAuthor | ICRP pediatric reference phantoms | - |
| dc.subject.keywordAuthor | Monte Carlo simulation | - |
| dc.subject.keywordAuthor | Pediatric patients | - |
| dc.subject.keywordAuthor | Internal dosimetry | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S1738573324000354?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
