Cited 0 time in
Automation of electrothermal cell sheet manipulator for seamless tissue assembly and handling
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Kang, Sehong | - |
| dc.contributor.author | Kim, Min-ku | - |
| dc.contributor.author | Lee, Chi-hwan | - |
| dc.contributor.author | Kong, Hyunjoon | - |
| dc.date.accessioned | 2025-12-18T02:00:25Z | - |
| dc.date.available | 2025-12-18T02:00:25Z | - |
| dc.date.issued | 2025-11 | - |
| dc.identifier.issn | 1387-2176 | - |
| dc.identifier.issn | 1572-8781 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/209894 | - |
| dc.description.abstract | The manipulation of fragile biological tissues such as engineered cell sheets remains a major challenge for regenerative medicine and tissue engineering. Manual handling with tools like tweezers often induces wrinkling or tearing, compromising tissue integrity. Here, we present an automated cell sheet manipulator that integrates a thermoresponsive microchanneled poly(N-isopropylacrylamide) (PNIPAAm) hydrogel with an embedded microheater, mounted on a programmable three-axis motorized stage. Upon localized heating and cooling, the hydrogel undergoes rapid, reversible volumetric transitions that enable suction-based gripping and release of cell sheets within a few seconds. The custom LabVIEW interface synchronizes stage movement and thermal cycling, allowing reproducible, hands-free operation. A compliance-based Z-axis apparatus ensured uniform low-magnitude contact forces, preventing mechanical damage during transfer. Using this system, human iPSC-derived neural sheets were reliably transferred onto human brain microvascular endothelial cell (hBMEC) monolayers. Compared to manual transfer, the automated manipulator preserved cell sheet flatness and minimized micro-wrinkling, resulting in safe retention of intercellular architecture and structural integrity. This work demonstrates a robust, user-friendly platform for automated and gentle handling of delicate biological sheets. By enabling the precise stacking of engineered tissues while preserving their morphology, this system provides a promising tool for advanced biofabrication workflows, supporting defect-free 3D tissue assembly and implantation. | - |
| dc.format.extent | 12 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Kluwer Academic Publishers | - |
| dc.title | Automation of electrothermal cell sheet manipulator for seamless tissue assembly and handling | - |
| dc.type | Article | - |
| dc.publisher.location | 네델란드 | - |
| dc.identifier.doi | 10.1007/s10544-025-00781-y | - |
| dc.identifier.scopusid | 2-s2.0-105022523082 | - |
| dc.identifier.wosid | 001619925000001 | - |
| dc.identifier.bibliographicCitation | Biomedical Microdevices, v.27, no.4, pp 1 - 12 | - |
| dc.citation.title | Biomedical Microdevices | - |
| dc.citation.volume | 27 | - |
| dc.citation.number | 4 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 12 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Engineering | - |
| dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
| dc.relation.journalWebOfScienceCategory | Engineering, Biomedical | - |
| dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
| dc.subject.keywordPlus | DEVICE | - |
| dc.subject.keywordAuthor | Human induced pluripotent stem cell | - |
| dc.subject.keywordAuthor | Human brain microvascular endothelial cell | - |
| dc.subject.keywordAuthor | Thermoresponsive hydrogel | - |
| dc.subject.keywordAuthor | Biofabrication | - |
| dc.subject.keywordAuthor | Automated biofabrication | - |
| dc.subject.keywordAuthor | Compliance-based z-axis apparatus | - |
| dc.identifier.url | https://link.springer.com/article/10.1007/s10544-025-00781-y | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.