Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Impact of Deep Learning-Based Image Conversion on Fully Automated Coronary Artery Calcium Scoring Using Thin-Slice, Sharp-Kernel, Non-Gated, Low-Dose Chest CT Scans: A Multi-Center Study

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Cherry-
dc.contributor.authorHong, Sehyun-
dc.contributor.authorChoi, Hangseok-
dc.contributor.authorYoo, Won-Seok-
dc.contributor.authorKim, Jin Young-
dc.contributor.authorChang, Suyon-
dc.contributor.authorPark, Chan Ho-
dc.contributor.authorHong, Su Jin-
dc.contributor.authorYang, Dong Hyun-
dc.contributor.authorYong, Hwan Seok-
dc.contributor.authorvan Assen, Marly-
dc.contributor.authorCecco, Carlo N. De-
dc.contributor.authorSuh, Young Joo-
dc.date.accessioned2025-12-23T05:30:33Z-
dc.date.available2025-12-23T05:30:33Z-
dc.date.issued2025-08-
dc.identifier.issn1229-6929-
dc.identifier.issn2005-8330-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/210030-
dc.description.abstractObjective: To evaluate the impact of deep learning-based image conversion on the accuracy of automated coronary artery calcium quantification using thin-slice, sharp-kernel, non-gated, low-dose chest computed tomography (LDCT) images collected from multiple institutions. Materials and Methods: A total of 225 pairs of LDCT and calcium scoring CT (CSCT) images scanned at 120 kVp and acquired from the same patient within a 6-month interval were retrospectively collected from four institutions. Image conversion was performed for LDCT images using proprietary software programs to simulate conventional CSCT. This process included 1) deep learning-based kernel conversion of low-dose, high-frequency, sharp kernels to simulate standard-dose, low-frequency kernels, and 2) thickness conversion using the raysum method to convert 1-mm or 1.25-mm thickness images to 3-mm thickness. Automated Agaston scoring was conducted on the LDCT scans before (LDCT-Orgauto) and after the image conversion (LDCTCONVauto). Manual scoring was performed on the CSCT images (CSCTmanual) and used as a reference standard. The accuracy of automated Agaston scores and risk severity categorization based on the automated scoring on LDCT scans was analyzed compared to the reference standard, using the Bland–Altman analysis, concordance correlation coefficient (CCC), and weighted kappa (κ) statistic. Results: LDCT-CONVauto demonstrated a reduced bias for Agaston score, compared with CSCTmanual, than LDCT-Orgauto did (-3.45 vs. 206.7). LDCT-CONVauto showed a higher CCC than LDCT-Orgauto did (0.881 [95% confidence interval {CI}, 0.750–0.960] vs. 0.269 [95% CI, 0.129–0.430]). In terms of risk category assignment, LDCT-Orgauto exhibited poor agreement with CSCTmanual Conclusion: Deep learning-based conversion of LDCT images originally obtained with thin slices and a sharp kernel can enhance the accuracy of automated coronary artery calcium score measurement using the images.-
dc.format.extent12-
dc.language영어-
dc.language.isoENG-
dc.publisher대한영상의학회-
dc.titleImpact of Deep Learning-Based Image Conversion on Fully Automated Coronary Artery Calcium Scoring Using Thin-Slice, Sharp-Kernel, Non-Gated, Low-Dose Chest CT Scans: A Multi-Center Study-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3348/kjr.2025.0177-
dc.identifier.scopusid2-s2.0-105008700969-
dc.identifier.wosid001539567000002-
dc.identifier.bibliographicCitationKorean Journal of Radiology, v.26, no.8, pp 759 - 770-
dc.citation.titleKorean Journal of Radiology-
dc.citation.volume26-
dc.citation.number8-
dc.citation.startPage759-
dc.citation.endPage770-
dc.type.docTypeArticle-
dc.identifier.kciidART003226992-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusITERATIVE MODEL RECONSTRUCTION-
dc.subject.keywordPlusALL-CAUSE MORTALITY-
dc.subject.keywordPlusCOMPUTED-TOMOGRAPHY-
dc.subject.keywordPlusRISK-FACTORS-
dc.subject.keywordPlusCALCIFICATION-
dc.subject.keywordPlusPREDICTION-
dc.subject.keywordPlusEVENTS-
dc.subject.keywordPlusALGORITHM-
dc.subject.keywordPlusDISEASE-
dc.subject.keywordAuthorCalcium-
dc.subject.keywordAuthorCoronary vessels-
dc.subject.keywordAuthorTomography-
dc.subject.keywordAuthorX-ray computed-
dc.subject.keywordAuthorThorax-
dc.subject.keywordAuthorArtificial intelligence-
dc.identifier.urlhttps://kjronline.org/DOIx.php?id=10.3348/kjr.2025.0177-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 영상의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Hong, Su Jin photo

Hong, Su Jin
서울 의과대학 (DEPARTMENT OF RADIOLOGY)
Read more

Altmetrics

Total Views & Downloads

BROWSE