Dose coefficients for the ICRP pediatric mesh-type reference computational phantoms under idealized external photon exposure geometries

Full metadata record
DC Field Value Language
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorShin, Bangho-
dc.contributor.authorYeom, Yeon Soo-
dc.contributor.authorBolch, Wesley E.-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2025-12-23T06:00:25Z-
dc.date.available2025-12-23T06:00:25Z-
dc.date.issued2025-09-
dc.identifier.issn1738-5733-
dc.identifier.issn2234-358X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/210041-
dc.description.abstractThe International Commission on Radiological Protection (ICRP) recently released the pediatric mesh-type reference computational phantoms (MRCPs) through ICRP Publication 156 to overcome the limitations of the pediatric voxel-type reference computational phantoms (VRCPs) of ICRP Publication 143. In the present study, these pediatric MRCPs were implemented into the Geant4 Monte Carlo code to produce a comprehensive dataset of dose coefficients for idealized external photon exposure geometries. This dataset includes 29 individual organ/tissue dose coefficients and effective dose coefficients, covering six irradiation geometries (i.e., AP, PA, LLAT, RLAT, ROT, and ISO) and 55 monoenergetic photon energies ranging from 10 keV to 10 GeV. The dataset comparison with the adult MRCPs of ICRP Publication 145 revealed substantial differences in effective dose coefficients throughout most energy ranges, primarily due to the age-related variations in organ/tissue depths, the differences reaching up to a factor ∼9. In addition, the comparisons with the pediatric VRCPs identified notable differences in effective dose coefficients, reaching up to a factor ∼4, for photon energies below 50 keV, due to the differences in phantom geometries and updates in simulation setups. For photon energies above 50 keV, deviations in effective dose coefficients between the pediatric MRCPs and VRCPs remained within 10 %.-
dc.format.extent8-
dc.language영어-
dc.language.isoENG-
dc.publisher한국원자력학회-
dc.titleDose coefficients for the ICRP pediatric mesh-type reference computational phantoms under idealized external photon exposure geometries-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.1016/j.net.2025.103621-
dc.identifier.scopusid2-s2.0-105002307449-
dc.identifier.wosid001471382300001-
dc.identifier.bibliographicCitationNuclear Engineering and Technology, v.57, no.9, pp 1 - 8-
dc.citation.titleNuclear Engineering and Technology-
dc.citation.volume57-
dc.citation.number9-
dc.citation.startPage1-
dc.citation.endPage8-
dc.type.docTypeArticle-
dc.identifier.kciidART003220819-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordAuthorDose coefficients-
dc.subject.keywordAuthorICRP reference phantoms-
dc.subject.keywordAuthorPediatric phantoms-
dc.subject.keywordAuthorMesh-typeMonte Carlo simulation-
dc.subject.keywordAuthorExternal photon exposures-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573325001895?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE