Dose coefficients for the ICRP pediatric mesh-type reference computational phantoms under idealized external photon exposure geometries
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Choi, Chansoo | - |
| dc.contributor.author | Shin, Bangho | - |
| dc.contributor.author | Yeom, Yeon Soo | - |
| dc.contributor.author | Bolch, Wesley E. | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.date.accessioned | 2025-12-23T06:00:25Z | - |
| dc.date.available | 2025-12-23T06:00:25Z | - |
| dc.date.issued | 2025-09 | - |
| dc.identifier.issn | 1738-5733 | - |
| dc.identifier.issn | 2234-358X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/210041 | - |
| dc.description.abstract | The International Commission on Radiological Protection (ICRP) recently released the pediatric mesh-type reference computational phantoms (MRCPs) through ICRP Publication 156 to overcome the limitations of the pediatric voxel-type reference computational phantoms (VRCPs) of ICRP Publication 143. In the present study, these pediatric MRCPs were implemented into the Geant4 Monte Carlo code to produce a comprehensive dataset of dose coefficients for idealized external photon exposure geometries. This dataset includes 29 individual organ/tissue dose coefficients and effective dose coefficients, covering six irradiation geometries (i.e., AP, PA, LLAT, RLAT, ROT, and ISO) and 55 monoenergetic photon energies ranging from 10 keV to 10 GeV. The dataset comparison with the adult MRCPs of ICRP Publication 145 revealed substantial differences in effective dose coefficients throughout most energy ranges, primarily due to the age-related variations in organ/tissue depths, the differences reaching up to a factor ∼9. In addition, the comparisons with the pediatric VRCPs identified notable differences in effective dose coefficients, reaching up to a factor ∼4, for photon energies below 50 keV, due to the differences in phantom geometries and updates in simulation setups. For photon energies above 50 keV, deviations in effective dose coefficients between the pediatric MRCPs and VRCPs remained within 10 %. | - |
| dc.format.extent | 8 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 한국원자력학회 | - |
| dc.title | Dose coefficients for the ICRP pediatric mesh-type reference computational phantoms under idealized external photon exposure geometries | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.1016/j.net.2025.103621 | - |
| dc.identifier.scopusid | 2-s2.0-105002307449 | - |
| dc.identifier.wosid | 001471382300001 | - |
| dc.identifier.bibliographicCitation | Nuclear Engineering and Technology, v.57, no.9, pp 1 - 8 | - |
| dc.citation.title | Nuclear Engineering and Technology | - |
| dc.citation.volume | 57 | - |
| dc.citation.number | 9 | - |
| dc.citation.startPage | 1 | - |
| dc.citation.endPage | 8 | - |
| dc.type.docType | Article | - |
| dc.identifier.kciid | ART003220819 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.subject.keywordAuthor | Dose coefficients | - |
| dc.subject.keywordAuthor | ICRP reference phantoms | - |
| dc.subject.keywordAuthor | Pediatric phantoms | - |
| dc.subject.keywordAuthor | Mesh-typeMonte Carlo simulation | - |
| dc.subject.keywordAuthor | External photon exposures | - |
| dc.identifier.url | https://www.sciencedirect.com/science/article/pii/S1738573325001895?via%3Dihub | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.