Increasing bushing temperature via a heating tube for performance enhancement of ion implanters

Full metadata record
DC Field Value Language
dc.contributor.authorShin, Yoon Hoo-
dc.contributor.authorSim, Hyo Jun-
dc.contributor.authorHwang, Jong Jin-
dc.contributor.authorMoon, Seung Jae-
dc.date.accessioned2026-01-21T02:30:34Z-
dc.date.available2026-01-21T02:30:34Z-
dc.date.issued2026-03-
dc.identifier.issn0142-727X-
dc.identifier.issn1879-2278-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/210399-
dc.description.abstractThis study aims to enhance the performance of an ion implanter by improving temperature control through a heating tube integrated within the bushing. In an ion implanter, gases such as PH<inf>3</inf>, AsH<inf>3</inf>, BF<inf>3</inf>, and GeF<inf>4</inf> are ionized by applying high voltages of up to 80 kV. Consequently, an ion beam is extracted from the electrode. However, residual gases are deposited inside the bushing under relatively low operating temperatures. Consequently, a leakage current flows through the bushing due to the deposited residual gas layer. This results in arcing from the potential differences across the bushing. To address this issue, this study designs and implements a heating tube within the bushing and circulates a heating fluid via the tube to increase the bushing's temperature. The proposed heating system prevents gas deposition and enhances the efficiency of the deposition process. The optimal condition—defined as achieving a bushing wall temperature of 60°C with minimal energy input—was determined as a FC-3283 flow rate of 24 LPM with an inlet temperature of 100°C. The effectiveness of this solution is evaluated through a combination of experiments and computational fluid dynamics simulations. The experimental results corroborate the simulation outcomes. This integrated experimental–simulation approach is expected to significantly enhance deposition process efficiency. These findings offer valuable insights for optimizing ion implantation performance and reducing the frequency of bushing replacements-
dc.format.extent13-
dc.language영어-
dc.language.isoENG-
dc.publisherELSEVIER SCIENCE INC-
dc.titleIncreasing bushing temperature via a heating tube for performance enhancement of ion implanters-
dc.typeArticle-
dc.publisher.location미국-
dc.identifier.doi10.1016/j.ijheatfluidflow.2025.110214-
dc.identifier.scopusid2-s2.0-105025530010-
dc.identifier.wosid001653470000001-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW, v.118, pp 1 - 13-
dc.citation.titleINTERNATIONAL JOURNAL OF HEAT AND FLUID FLOW-
dc.citation.volume118-
dc.citation.startPage1-
dc.citation.endPage13-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMechanics-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.relation.journalWebOfScienceCategoryMechanics-
dc.subject.keywordAuthorBushing-
dc.subject.keywordAuthorHeating tube-
dc.subject.keywordAuthorHeating liquid-
dc.subject.keywordAuthorComputational fluid dynamics-
dc.subject.keywordAuthorIon implanter-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S0142727X25004722?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Moon, Seung Jae photo

Moon, Seung Jae
COLLEGE OF ENGINEERING (SCHOOL OF MECHANICAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE