Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

하박 장착용 스마트 개인무장의 발사충격에 의한 인체거동 해석Simulation of Shot Impact by a Wearable Smart Individual Weapon Mounted on a Forearm

Other Titles
Simulation of Shot Impact by a Wearable Smart Individual Weapon Mounted on a Forearm
Authors
구성찬김태경최민기김상현최성호이용선김재정
Issue Date
Dec-2019
Publisher
한국군사과학기술학회
Keywords
Wearable Smart Individual Weapon(장착용 스마트 개인 무장); Fire Impact(발사 충격); Human Body Model (인체모델); Human Joint Behavior(인체 관절 거동)
Citation
한국군사과학기술학회지, v.22, no.6, pp 806 - 814
Pages
9
Indexed
KCI
Journal Title
한국군사과학기술학회지
Volume
22
Number
6
Start Page
806
End Page
814
URI
https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/2103
DOI
10.9766/KIMST.2019.22.6.806
ISSN
1598-9127
2636-0640
Abstract
One of the future weapon systems is the individual smart weapon which has a structure mounted on the forearm of soldiers. The structure may cause injuries or affect the accuracy of fire due to its impact on joints when shooting. This paper proposes human-impact interaction modeling and a verification methodology in order to estimate the impact of fire applied to the forearm. For this purpose, a human musculoskeletal model was constructed and the joints’ behavior in various shooting positions was simulated. In order to verify the simulation results, an impact testing device substituting the smart weapon was made and the experiment was performed on a real human body. This paper compares the simulation results performed under various impact conditions and the experimental values in terms of accuracy and introduces methods to complement them. The results of the study are expected to be a basis for a reliable human-impact interaction modeling, and smart individual weapon development.
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 기계공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE