Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

신재생열원 적용에 따른 캐스케이드 히트펌프의 급탕 및 공기난방에 대한 실험 및 에너지 성능 연구

Full metadata record
DC Field Value Language
dc.contributor.author김범준-
dc.contributor.author정재원-
dc.date.accessioned2026-03-04T02:00:24Z-
dc.date.available2026-03-04T02:00:24Z-
dc.date.issued2024-08-
dc.identifier.issn1976-6483-
dc.identifier.issn2586-0666-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/211037-
dc.description.abstractThe purpose of this study is to conduct an experimental performance evaluation applying renewable heat sources to the cascade heat pump system compared to the air source in the winter. The renewable heat sources applied are geothermal and solar heat sources. The cascade heat pump supplies hot water from a high-cycle heat pump and air heating from a low-cycle heat pump. For the experiment, the cascade heat pump was manufactured and installed on the basement floor of the experimental building. The air source was supplied by an outdoor unit, the geothermal source by a geothermal simulator, and the solar source by a photovoltaic-thermal panel. The average value of the measured values for 10 minutes after the system was stabilized was used. The experimental results showed that applying renewable heat sources resulted in improved results in terms of heat capacity and supply fluid temperature, and the system COP was confirmed to have a performance improvement effect of 10.7% for the geothermal source and 6.1% for the solar source compared to the air source. This is the result of improved system performance while satisfying both the indoor heating load and the domestic hot water load flow rate. On the other hand, the temperature of the solar heat source was higher than that of the geothermal source, but low performance was derived. This is because the circulation flow of the solar heat source was circulated at 27% of that of the geothermal source, so relatively little heat was supplied to the heat pump. The cascade heat pump system of this study was installed with the indoor unit after the intermediate heat exchanger for domestic hot water. Therefore, a large amount of heat was supplied to the domestic hot water side. The performance of heating and domestic hot water can be affected depending on the installation order of the heat exchanger, regardless of the type and supply temperature of the heat source.-
dc.format.extent10-
dc.language한국어-
dc.language.isoKOR-
dc.publisher한국건축친환경설비학회-
dc.title신재생열원 적용에 따른 캐스케이드 히트펌프의 급탕 및 공기난방에 대한 실험 및 에너지 성능 연구-
dc.title.alternativeExperimental and Energy Performance Study of Cascade Heat Pump System with Renewable Heat Sources for Air and Water Heating-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.22696/jkiaebs.20240030-
dc.identifier.bibliographicCitation한국건축친환경설비학회 논문집, v.18, no.4, pp 353 - 362-
dc.citation.title한국건축친환경설비학회 논문집-
dc.citation.volume18-
dc.citation.number4-
dc.citation.startPage353-
dc.citation.endPage362-
dc.identifier.kciidART003109381-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthor캐스케이드 히트펌프-
dc.subject.keywordAuthor신재생열원-
dc.subject.keywordAuthor공기난방-
dc.subject.keywordAuthor급탕-
dc.subject.keywordAuthor성능 평가-
dc.subject.keywordAuthorCascade heat pump-
dc.subject.keywordAuthorRenewable heat source-
dc.subject.keywordAuthorIndoor air heating-
dc.subject.keywordAuthorDomestic hot water-
dc.subject.keywordAuthorPerformance evaluation-
dc.identifier.urlhttps://www.jkiaebs.org/articles/article/BbPV/#Information-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건축공학부 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Jeong, Jae Weon photo

Jeong, Jae Weon
COLLEGE OF ENGINEERING (SCHOOL OF ARCHITECTURAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE