Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Verification of Markerless Gait Analysis: Multi-Camera and Single-Camera Approaches in Comparison to Marker-Based Gait Analysis

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Yong Seok-
dc.contributor.authorYu, Yeon Woo-
dc.contributor.authorCha, Hari-
dc.contributor.authorLee, Joon Seok-
dc.contributor.authorYoon, Chan-
dc.contributor.authorKim, Byung-Hoon-
dc.contributor.authorPark, Jae Hyeon-
dc.contributor.authorLee, Ki-Kwang-
dc.date.accessioned2026-03-10T02:00:16Z-
dc.date.available2026-03-10T02:00:16Z-
dc.date.issued2026-02-
dc.identifier.issn1010-660X-
dc.identifier.issn1648-9144-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/211130-
dc.description.abstractBackground and Objectives: This study aimed to verify the validity of markerless gait analysis using both single-camera markerless system (S-ML) and multi-camera markerless system (M-ML) approaches by comparing them with a gold-standard marker-based system (MB). Materials and Methods: Sixteen healthy adults walked at their gait speed, and their gaits were simultaneously analyzed using three systems: S-ML, M-ML, and MB. Intraclass correlation coefficients were used to assess the reliability of the spatiotemporal parameters, and the root mean squared error (RMSE) was calculated to quantify the kinematic differences relative to the MB systems. Results: Both S-ML and M-ML demonstrated good-to-excellent reliability in spatiotemporal parameters, including step length, stance time, and gait speed, whereas stride length and swing time measured by S-ML revealed moderate reliability. In terms of joint kinematics, S-ML demonstrated a performance comparable to that of M-ML, particularly at the hip and knee in the sagittal plane. For certain parameters, such as knee abduction/adduction in the frontal plane, the S-ML demonstrated lower RMSE values than M-ML. In contrast, the ankle joint angles estimated using S-ML exhibited reduced agreement. Conclusions: In conclusion, markerless gait analysis can serve as an alternative to conventional gait analysis. However, certain parameters need to be improved.-
dc.format.extent12-
dc.language영어-
dc.language.isoENG-
dc.publisherMDPI AG-
dc.titleVerification of Markerless Gait Analysis: Multi-Camera and Single-Camera Approaches in Comparison to Marker-Based Gait Analysis-
dc.typeArticle-
dc.publisher.location스위스-
dc.identifier.doi10.3390/medicina62020418-
dc.identifier.scopusid2-s2.0-105031263275-
dc.identifier.wosid001700733200001-
dc.identifier.bibliographicCitationMEDICINA-LITHUANIA, v.62, no.2, pp 1 - 12-
dc.citation.titleMEDICINA-LITHUANIA-
dc.citation.volume62-
dc.citation.number2-
dc.citation.startPage1-
dc.citation.endPage12-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusRELIABILITY-
dc.subject.keywordAuthorgait analysis-
dc.subject.keywordAuthorpose estimation algorithm-
dc.subject.keywordAuthormarkerless motion capture-
dc.subject.keywordAuthormarker based algorithm-
dc.subject.keywordAuthorverification-
dc.identifier.urlhttps://www.mdpi.com/1648-9144/62/2/418-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 재활의학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Park, Jae Hyeon photo

Park, Jae Hyeon
서울 의과대학 (DEPARTMENT OF REHABILITATION MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE