Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Unified AC-based framework for self-sensing UHPFRC: Effects of fiber length and electrode geometry under tension and compression

Full metadata record
DC Field Value Language
dc.contributor.authorLai, Thanh Tu-
dc.contributor.authorCho, Jun Sik-
dc.contributor.authorKim, Min Kyoung-
dc.contributor.authorKim, Dong Joo-
dc.date.accessioned2026-03-31T08:00:31Z-
dc.date.available2026-03-31T08:00:31Z-
dc.date.issued2026-04-
dc.identifier.issn2352-7102-
dc.identifier.issn2352-7102-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/211846-
dc.description.abstractSmart ultra-high-performance fiber-reinforced concrete (S-UHPFRC) exhibits strong potential for self-sensing and structural health monitoring (SHM); however, its electromechanical behavior is strongly influenced by the fiber characteristics and electrode configuration. The coupled effects of the fiber length and electrode geometry, particularly under both compression and tension, remain insufficiently understood, limiting the translation of laboratory findings into practical SHM applications. To address this gap, this study systematically evaluates the influence of three fiber lengths (6, 13, and 19.5 mm) and three embedded electrode geometries (I-, U-, and W-type, comprising one, two, and three embedded legs, respectively) on the electromechanical response of S-UHPFRC under uniaxial compression and tension using alternating current measurements. The fiber length significantly affects both the direction and stability of the sensing response, exhibiting opposite trends in compression and tension. Under compression, mixtures with shorter fibers produce the largest fractional change in electrical resistance (FCR), with CU-06 reaching −7.67 % and a low variability of 0.99 % at 139.9 MPa. In contrast, longer fibers enhance tensile stress sensitivity, with TU-19 achieving an FCR of 29.78 %. Overall, the results highlight that coordinated optimization of fiber length and electrode geometry is essential for achieving reliable, high-performance self-sensing in S-UHPFRC and provide practical guidance for its implementation in large-scale SHM systems. Among the three electrode configurations, the U-type electrode consistently exhibited the most reliable and stable sensing performance under both loading conditions, clearly outperforming the other configurations.-
dc.format.extent29-
dc.language영어-
dc.language.isoENG-
dc.publisherElsevier Ltd-
dc.titleUnified AC-based framework for self-sensing UHPFRC: Effects of fiber length and electrode geometry under tension and compression-
dc.typeArticle-
dc.publisher.location네덜란드-
dc.identifier.doi10.1016/j.jobe.2026.115801-
dc.identifier.scopusid2-s2.0-105032906186-
dc.identifier.wosid001720568600001-
dc.identifier.bibliographicCitationJournal of Building Engineering, v.123, pp 1 - 29-
dc.citation.titleJournal of Building Engineering-
dc.citation.volume123-
dc.citation.startPage1-
dc.citation.endPage29-
dc.type.docTypeArticle-
dc.description.isOpenAccessN-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaConstruction & Building Technology-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryConstruction & Building Technology-
dc.relation.journalWebOfScienceCategoryEngineering, Civil-
dc.subject.keywordPlusREINFORCED CONCRETE-
dc.subject.keywordPlusELECTRICAL-RESISTIVITY-
dc.subject.keywordPlusSTRAIN-
dc.subject.keywordPlusBEHAVIOR-
dc.subject.keywordPlusDAMAGE-
dc.subject.keywordPlusRESISTANCE-
dc.subject.keywordPlusCORROSION-
dc.subject.keywordPlusSENSORS-
dc.subject.keywordAuthorEmbedded electrode geometry-
dc.subject.keywordAuthorFiber length effect-
dc.subject.keywordAuthorSelf-sensing capability-
dc.subject.keywordAuthorSelf-stress sensing-
dc.subject.keywordAuthorSmart ultra-high-performance fiber-reinforced concrete-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S2352710226006224?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 건설환경공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, Dong Joo photo

KIM, Dong Joo
COLLEGE OF ENGINEERING (DEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE