Dose Coefficients for Irradiation of Tooth Enamel within ICRP Adult Mesh-type Reference Computational Phantoms for Idealized External Photon Exposures
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Shin, Bangho | - |
| dc.contributor.author | Choi, Chansoo | - |
| dc.contributor.author | Yeom, Yeon Soo | - |
| dc.contributor.author | Kim, Chan Hyeong | - |
| dc.contributor.author | Bolch, Wesley E. | - |
| dc.date.accessioned | 2026-04-21T01:30:16Z | - |
| dc.date.available | 2026-04-21T01:30:16Z | - |
| dc.date.issued | 2026-05 | - |
| dc.identifier.issn | 0017-9078 | - |
| dc.identifier.issn | 1538-5159 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/212264 | - |
| dc.description.abstract | In the present study, the tooth enamel dose coefficients (DCs) were established for idealized external photon exposures using the International Commission on Radiological Protection (ICRP) adult mesh-type reference computational phantoms (MRCPs), coupled with Geant4 Monte Carlo radiation transport code, for use in electron paramagnetic resonance (EPR) dosimetry. The DCs were calculated for 10 distinct tooth enamel regions (buccal and lingual enamel regions for front, front-left, front-right, left, and right teeth sites) for six irradiation geometries of uniform external photon fields (AP, PA, LLAT, RLAT, ROT, and ISO) across the energy range of 10 keV to 10 GeV. The results revealed substantial variations among different enamel regions, particularly for photon energies below 0.1 MeV, with differences in DC magnitude of up to 2,251-fold between the front buccal and left lingual enamels at 0.015 MeV in the adult male MRCP. Furthermore, compared to DCs derived from the Golem voxel phantom, the MRCP-based DCs exhibited differences of up to several orders of magnitude at low energies, primarily due to the more detailed anatomical representation of enamel structures within the adult MRCPs. The enamel DCs are expected to be used beneficially to estimate individual radiation doses for exposed adult populations through the conversion of the measured EPR signals in extracted teeth, to include both individual organ doses as well as the whole-body effective dose. | - |
| dc.format.extent | 10 | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | Lippincott Williams and Wilkins | - |
| dc.title | Dose Coefficients for Irradiation of Tooth Enamel within ICRP Adult Mesh-type Reference Computational Phantoms for Idealized External Photon Exposures | - |
| dc.type | Article | - |
| dc.publisher.location | 미국 | - |
| dc.identifier.doi | 10.1097/HP.0000000000002068 | - |
| dc.identifier.scopusid | 2-s2.0-105034816482 | - |
| dc.identifier.wosid | 001728981800014 | - |
| dc.identifier.bibliographicCitation | Health physics, v.130, no.5, pp 588 - 597 | - |
| dc.citation.title | Health physics | - |
| dc.citation.volume | 130 | - |
| dc.citation.number | 5 | - |
| dc.citation.startPage | 588 | - |
| dc.citation.endPage | 597 | - |
| dc.type.docType | Article | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
| dc.relation.journalResearchArea | Public, Environmental & Occupational Health | - |
| dc.relation.journalResearchArea | Nuclear Science & Technology | - |
| dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
| dc.relation.journalWebOfScienceCategory | Public, Environmental & Occupational Health | - |
| dc.relation.journalWebOfScienceCategory | Nuclear Science & Technology | - |
| dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
| dc.subject.keywordPlus | CONVERSION COEFFICIENTS | - |
| dc.subject.keywordPlus | DOSIMETRIC RESPONSE | - |
| dc.subject.keywordPlus | EPR | - |
| dc.subject.keywordAuthor | enamel dose coefficients | - |
| dc.subject.keywordAuthor | International Commission on Radiological Protection (ICRP) reference phantoms | - |
| dc.subject.keywordAuthor | Monte Carlo simulation | - |
| dc.subject.keywordAuthor | photon external exposure | - |
| dc.subject.keywordAuthor | tetrahedral mesh | - |
| dc.identifier.url | https://journals.lww.com/health-physics/fulltext/2026/05000/dose_coefficients_for_irradiation_of_tooth_enamel.8.aspx | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.