Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Towards accurate dose assessment for emergency industrial radiography source retrieval operations: A preliminary study of 4D Monte Carlo dose calculations

Full metadata record
DC Field Value Language
dc.contributor.authorMoon, Sungho-
dc.contributor.authorHan, Haegin-
dc.contributor.authorChoi, Chansoo-
dc.contributor.authorShin, Bangho-
dc.contributor.authorSon, Gahee-
dc.contributor.authorKim, Hyeonil-
dc.contributor.authorKim, Suhyeon-
dc.contributor.authorKim, Jaehyo-
dc.contributor.authorYoon, In Gyu-
dc.contributor.authorLee, Kyung Hwan-
dc.contributor.authorKim, Chan Hyeong-
dc.date.accessioned2026-04-28T06:30:20Z-
dc.date.available2026-04-28T06:30:20Z-
dc.date.issued2024-12-
dc.identifier.issn1738-5733-
dc.identifier.issn2234-358X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/212422-
dc.description.abstractThe exposure devices utilizing high-activity gamma radiation sources for industrial radiography frequently encounter issues such as stuck or disconnected sources, posing a substantial risk of radiation exposure to the workers executing emergency source retrieval operations, emphasizing the importance of accurate dose assessment. In the present study, the radiation dose to the main worker during the process of source retrieval was calculated and compared for five emergency source retrieval procedures to retrieve stuck or disconnected sources, using 4D Monte Carlo dose calculation and a mesh-type reference computational phantom. For a stuck source, the dose values of the two source retrieval procedures (i.e., repair and cut methods) were found to be relatively small, which indicates that the worker might select either method based on personal preference or situational convenience. Conversely, for a disconnected source, the dose values of the three source retrieval procedures (i.e., fishing, connect/push, and hot stick methods) were much larger and show significant differences. Notably, the fishing method was associated with the lowest dose, whereas the hot stick method resulted in significantly higher doses, differences being as large as ∼5 times. These results underscore the fishing method as a preferable option, particularly over the hot stick method.-
dc.format.extent9-
dc.language영어-
dc.language.isoENG-
dc.publisher한국원자력학회-
dc.titleTowards accurate dose assessment for emergency industrial radiography source retrieval operations: A preliminary study of 4D Monte Carlo dose calculations-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.1016/j.net.2024.09.004-
dc.identifier.scopusid2-s2.0-85203499519-
dc.identifier.wosid001361066500001-
dc.identifier.bibliographicCitationNuclear Engineering and Technology, v.56, no.12, pp 5428 - 5436-
dc.citation.titleNuclear Engineering and Technology-
dc.citation.volume56-
dc.citation.number12-
dc.citation.startPage5428-
dc.citation.endPage5436-
dc.type.docTypeArticle-
dc.identifier.kciidART003137830-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordAuthorComputational phantom-
dc.subject.keywordAuthorIndustrial radiography-
dc.subject.keywordAuthorMonte Carlo-
dc.subject.keywordAuthorMotion capture-
dc.subject.keywordAuthorNDT-
dc.identifier.urlhttps://www.sciencedirect.com/science/article/pii/S1738573324004480?via%3Dihub-
Files in This Item
Go to Link
Appears in
Collections
서울 공과대학 > 서울 원자력공학과 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Chan Hyeong photo

Kim, Chan Hyeong
COLLEGE OF ENGINEERING (DEPARTMENT OF NUCLEAR ENGINEERING)
Read more

Altmetrics

Total Views & Downloads

BROWSE