Cited 0 time in
타력 구동을 고려한 연료전지 시스템 수소 재순환 블로어의 기동 방법
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | 오은솔 | - |
| dc.contributor.author | 이늘푸른하늘 | - |
| dc.contributor.author | 유성진 | - |
| dc.contributor.author | 이현준 | - |
| dc.contributor.author | 윤영두 | - |
| dc.date.accessioned | 2026-04-30T07:30:16Z | - |
| dc.date.available | 2026-04-30T07:30:16Z | - |
| dc.date.issued | 2026-04 | - |
| dc.identifier.issn | 1229-2214 | - |
| dc.identifier.issn | 2288-6281 | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/212478 | - |
| dc.description.abstract | Externally induced rotation can occur in the hydrogen recirculation blowers of fuel cell systems prior to motor startup, as the rotor is driven by hydrogen flow resulting from the tank pressure. Under these conditions, rotor alignment at startup becomes difficult. In this study, the rotor is set to stand still by eliminating the pressure difference caused by the hydrogen tank, as this process consumes time. However, for rapid startup, a method that enables motor initiation while the rotor is already rotating is needed. This study proposes a startup method for a hydrogen recirculation blower that accounts for externally induced rotation. This scheme is identified by applying three zero-voltage vectors and estimating the rotor speed and position. The duration of the applied zero-voltage vector and the interval between injections are adjusted according to the magnitude of the back electromotive force (EMF). The method enables stable startup over the entire speed range. The proposed system is experimentally validated on an actual blower with a 200 W IPMSM. | - |
| dc.format.extent | 7 | - |
| dc.language | 한국어 | - |
| dc.language.iso | KOR | - |
| dc.publisher | 전력전자학회 | - |
| dc.title | 타력 구동을 고려한 연료전지 시스템 수소 재순환 블로어의 기동 방법 | - |
| dc.title.alternative | Startup Method for the Hydrogen Recirculation Blower in Fuel Cell Systems Considering Externally Induced Rotation | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.6113/TKPE.2026.31.2.102 | - |
| dc.identifier.bibliographicCitation | 전력전자학회 논문지, v.31, no.2, pp 102 - 108 | - |
| dc.citation.title | 전력전자학회 논문지 | - |
| dc.citation.volume | 31 | - |
| dc.citation.number | 2 | - |
| dc.citation.startPage | 102 | - |
| dc.citation.endPage | 108 | - |
| dc.type.docType | Y | - |
| dc.identifier.kciid | ART003326374 | - |
| dc.description.isOpenAccess | N | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.subject.keywordAuthor | Fuel cell system | - |
| dc.subject.keywordAuthor | Hydrogen recirculation blower | - |
| dc.subject.keywordAuthor | Startup method | - |
| dc.subject.keywordAuthor | Sensorless control | - |
| dc.subject.keywordAuthor | Externally induced rotation | - |
| dc.identifier.url | https://www.dbpia.co.kr/journal/articleDetail?nodeId=NODE12733094 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
