Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Optimal cut-offs of vibration-controlled transient elastography and magnetic resonance elastography in diagnosing advanced liver fibrosis in patients with nonalcoholic fatty liver disease: A systematic review and meta-analysis

Full metadata record
DC Field Value Language
dc.contributor.authorChon, Young Eun-
dc.contributor.authorJin, Young-Joo-
dc.contributor.authorAn, Jihyun-
dc.contributor.authorKim, Hee Yeon-
dc.contributor.authorChoi, Miyoung-
dc.contributor.authorJun, Dae Won-
dc.contributor.authorKim, Mi Na-
dc.contributor.authorHan, Ji Won-
dc.contributor.authorLee, Han Ah-
dc.contributor.authorYu, Jung Hwan-
dc.contributor.authorKim, Seung Up-
dc.date.accessioned2026-05-12T01:30:30Z-
dc.date.available2026-05-12T01:30:30Z-
dc.date.issued2024-09-
dc.identifier.issn2287-2728-
dc.identifier.issn2287-285X-
dc.identifier.urihttps://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/212692-
dc.description.abstractBackground/aims: Opinions differ regarding vibration-controlled transient elastography and magnetic resonance elastography (VCTE/MRE) cut-offs for diagnosing advanced fibrosis (AF) in patients with non-alcoholic fatty liver disease (NAFLD). We investigated the diagnostic performance and optimal cut-off values of VCTE and MRE for diagnosing AF. Methods: Literature databases, including Medline, EMBASE, Cochrane Library, and KoreaMed, were used to identify relevant studies published up to June 13, 2023. We selected studies evaluating VCTE and MRE regarding the degree of liver fibrosis using liver biopsy as the reference. The sensitivity, specificity, and area under receiver operating characteristics curves (AUCs) of the pooled data for VCTE and MRE for each fibrosis stage and optimal cut-offs for AF were investigated. Results: A total of 19,199 patients from 63 studies using VCTE showed diagnostic AUC of 0.83 (95% confidence interval: 0.80–0.86), 0.83 (0.80–0.86), 0.87 (0.84–0.90), and 0.94 (0.91–0.96) for ≥F1, ≥F2, ≥F3, and F4 stages, respectively. Similarly, 1,484 patients from 14 studies using MRE showed diagnostic AUC of 0.89 (0.86–0.92), 0.92 (0.89–0.94), 0.89 (0.86–0.92), and 0.94 (0.91–0.96) for ≥F1, ≥F2, ≥F3, and F4 stages, respectively. The diagnostic AUC for AF using VCTE was highest at 0.90 with a cut-off of 7.1–7.9 kPa, and that of MRE was highest at 0.94 with a cut-off of 3.62–3.8 kPa. Conclusions: VCTE (7.1–7.9 kPa) and MRE (3.62–3.8 kPa) with the suggested cut-offs showed favorable accuracy for diagnosing AF in patients with NAFLD. This result will serve as a basis for clinical guidelines for non-invasive tests and differential diagnosis of AF.-
dc.language영어-
dc.language.isoENG-
dc.publisher대한간학회-
dc.titleOptimal cut-offs of vibration-controlled transient elastography and magnetic resonance elastography in diagnosing advanced liver fibrosis in patients with nonalcoholic fatty liver disease: A systematic review and meta-analysis-
dc.typeArticle-
dc.publisher.location대한민국-
dc.identifier.doi10.3350/CMH.2024.0392-
dc.identifier.scopusid2-s2.0-85208604541-
dc.identifier.wosid001344033300007-
dc.identifier.bibliographicCitationClinical and Molecular Hepatology, v.30, pp S117 - S133-
dc.citation.titleClinical and Molecular Hepatology-
dc.citation.volume30-
dc.citation.startPageS117-
dc.citation.endPageS133-
dc.type.docTypeReview-
dc.identifier.kciidART003121342-
dc.description.isOpenAccessY-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaGastroenterology & Hepatology-
dc.relation.journalWebOfScienceCategoryGastroenterology & Hepatology-
dc.subject.keywordPlusArticle-
dc.subject.keywordPlusbody mass-
dc.subject.keywordPlusdiabetes mellitus-
dc.subject.keywordPlusdiagnostic accuracy-
dc.subject.keywordPlusdifferential diagnosis-
dc.subject.keywordPluselastography-
dc.subject.keywordPlusfatty liver-
dc.subject.keywordPlushuman-
dc.subject.keywordPlusliver biopsy-
dc.subject.keywordPlusliver cirrhosis-
dc.subject.keywordPlusliver fibrosis-
dc.subject.keywordPlusmagnetic resonance elastography-
dc.subject.keywordPlusmeta analysis-
dc.subject.keywordPlusnonalcoholic fatty liver-
dc.subject.keywordPluspredictive value-
dc.subject.keywordPlusreceiver operating characteristic-
dc.subject.keywordPlussensitivity and specificity-
dc.subject.keywordPlussystematic review-
dc.subject.keywordPlustransient elastography-
dc.subject.keywordPlusvibration-
dc.subject.keywordAuthorAdvanced fibrosis-
dc.subject.keywordAuthorMagnetic resonance elastography-
dc.subject.keywordAuthorMeta-analysis-
dc.subject.keywordAuthorNon-alcoholic fatty liver disease-
dc.subject.keywordAuthorVibration-controlled transient elastography-
dc.identifier.urlhttps://e-cmh.org/journal/view.php?doi=10.3350/cmh.2024.0392-
Files in This Item
Go to Link
Appears in
Collections
서울 의과대학 > 서울 내과학교실 > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher An, Ji hyun photo

An, Ji hyun
서울 의과대학 (DEPARTMENT OF INTERNAL MEDICINE)
Read more

Altmetrics

Total Views & Downloads

BROWSE