Cited 0 time in
Optimal cut-offs of vibration-controlled transient elastography and magnetic resonance elastography in diagnosing advanced liver fibrosis in patients with nonalcoholic fatty liver disease: A systematic review and meta-analysis
| DC Field | Value | Language |
|---|---|---|
| dc.contributor.author | Chon, Young Eun | - |
| dc.contributor.author | Jin, Young-Joo | - |
| dc.contributor.author | An, Jihyun | - |
| dc.contributor.author | Kim, Hee Yeon | - |
| dc.contributor.author | Choi, Miyoung | - |
| dc.contributor.author | Jun, Dae Won | - |
| dc.contributor.author | Kim, Mi Na | - |
| dc.contributor.author | Han, Ji Won | - |
| dc.contributor.author | Lee, Han Ah | - |
| dc.contributor.author | Yu, Jung Hwan | - |
| dc.contributor.author | Kim, Seung Up | - |
| dc.date.accessioned | 2026-05-12T01:30:30Z | - |
| dc.date.available | 2026-05-12T01:30:30Z | - |
| dc.date.issued | 2024-09 | - |
| dc.identifier.issn | 2287-2728 | - |
| dc.identifier.issn | 2287-285X | - |
| dc.identifier.uri | https://scholarworks.bwise.kr/hanyang/handle/2021.sw.hanyang/212692 | - |
| dc.description.abstract | Background/aims: Opinions differ regarding vibration-controlled transient elastography and magnetic resonance elastography (VCTE/MRE) cut-offs for diagnosing advanced fibrosis (AF) in patients with non-alcoholic fatty liver disease (NAFLD). We investigated the diagnostic performance and optimal cut-off values of VCTE and MRE for diagnosing AF. Methods: Literature databases, including Medline, EMBASE, Cochrane Library, and KoreaMed, were used to identify relevant studies published up to June 13, 2023. We selected studies evaluating VCTE and MRE regarding the degree of liver fibrosis using liver biopsy as the reference. The sensitivity, specificity, and area under receiver operating characteristics curves (AUCs) of the pooled data for VCTE and MRE for each fibrosis stage and optimal cut-offs for AF were investigated. Results: A total of 19,199 patients from 63 studies using VCTE showed diagnostic AUC of 0.83 (95% confidence interval: 0.80–0.86), 0.83 (0.80–0.86), 0.87 (0.84–0.90), and 0.94 (0.91–0.96) for ≥F1, ≥F2, ≥F3, and F4 stages, respectively. Similarly, 1,484 patients from 14 studies using MRE showed diagnostic AUC of 0.89 (0.86–0.92), 0.92 (0.89–0.94), 0.89 (0.86–0.92), and 0.94 (0.91–0.96) for ≥F1, ≥F2, ≥F3, and F4 stages, respectively. The diagnostic AUC for AF using VCTE was highest at 0.90 with a cut-off of 7.1–7.9 kPa, and that of MRE was highest at 0.94 with a cut-off of 3.62–3.8 kPa. Conclusions: VCTE (7.1–7.9 kPa) and MRE (3.62–3.8 kPa) with the suggested cut-offs showed favorable accuracy for diagnosing AF in patients with NAFLD. This result will serve as a basis for clinical guidelines for non-invasive tests and differential diagnosis of AF. | - |
| dc.language | 영어 | - |
| dc.language.iso | ENG | - |
| dc.publisher | 대한간학회 | - |
| dc.title | Optimal cut-offs of vibration-controlled transient elastography and magnetic resonance elastography in diagnosing advanced liver fibrosis in patients with nonalcoholic fatty liver disease: A systematic review and meta-analysis | - |
| dc.type | Article | - |
| dc.publisher.location | 대한민국 | - |
| dc.identifier.doi | 10.3350/CMH.2024.0392 | - |
| dc.identifier.scopusid | 2-s2.0-85208604541 | - |
| dc.identifier.wosid | 001344033300007 | - |
| dc.identifier.bibliographicCitation | Clinical and Molecular Hepatology, v.30, pp S117 - S133 | - |
| dc.citation.title | Clinical and Molecular Hepatology | - |
| dc.citation.volume | 30 | - |
| dc.citation.startPage | S117 | - |
| dc.citation.endPage | S133 | - |
| dc.type.docType | Review | - |
| dc.identifier.kciid | ART003121342 | - |
| dc.description.isOpenAccess | Y | - |
| dc.description.journalRegisteredClass | scie | - |
| dc.description.journalRegisteredClass | scopus | - |
| dc.description.journalRegisteredClass | kci | - |
| dc.relation.journalResearchArea | Gastroenterology & Hepatology | - |
| dc.relation.journalWebOfScienceCategory | Gastroenterology & Hepatology | - |
| dc.subject.keywordPlus | Article | - |
| dc.subject.keywordPlus | body mass | - |
| dc.subject.keywordPlus | diabetes mellitus | - |
| dc.subject.keywordPlus | diagnostic accuracy | - |
| dc.subject.keywordPlus | differential diagnosis | - |
| dc.subject.keywordPlus | elastography | - |
| dc.subject.keywordPlus | fatty liver | - |
| dc.subject.keywordPlus | human | - |
| dc.subject.keywordPlus | liver biopsy | - |
| dc.subject.keywordPlus | liver cirrhosis | - |
| dc.subject.keywordPlus | liver fibrosis | - |
| dc.subject.keywordPlus | magnetic resonance elastography | - |
| dc.subject.keywordPlus | meta analysis | - |
| dc.subject.keywordPlus | nonalcoholic fatty liver | - |
| dc.subject.keywordPlus | predictive value | - |
| dc.subject.keywordPlus | receiver operating characteristic | - |
| dc.subject.keywordPlus | sensitivity and specificity | - |
| dc.subject.keywordPlus | systematic review | - |
| dc.subject.keywordPlus | transient elastography | - |
| dc.subject.keywordPlus | vibration | - |
| dc.subject.keywordAuthor | Advanced fibrosis | - |
| dc.subject.keywordAuthor | Magnetic resonance elastography | - |
| dc.subject.keywordAuthor | Meta-analysis | - |
| dc.subject.keywordAuthor | Non-alcoholic fatty liver disease | - |
| dc.subject.keywordAuthor | Vibration-controlled transient elastography | - |
| dc.identifier.url | https://e-cmh.org/journal/view.php?doi=10.3350/cmh.2024.0392 | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
222, Wangsimni-ro, Seongdong-gu, Seoul, 04763, Korea+82-2-2220-1366
COPYRIGHT © 2024 HANYANG UNIVERSITY.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.
